Fluke i3000 Flex AC Current Clamp, 4 Pack | Fluke
English

Fluke i3000 Flex AC Current Clamp, 4 Pack

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 21.87ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Fluke i3000 Flex AC Current Clamp, 4 Pack

Key features

  • Three ranges
    • 30 A
    • 300 A
    • 3000 A, 1, 10 or 100 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm (7 in)
  • CAT III 600 V safety rating

Product overview: Fluke i3000 Flex AC Current Clamp, 4 Pack

The i3000s Flex is an AC current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Specifications: Fluke i3000 Flex AC Current Clamp, 4 Pack

Electrical Specifications
Current ranges30 A
300 A
3000 A
AC rms
Output sensitivity (AC-coupled)100 mV
10 m
1 mV per A
Load impedance100 kΩ minimum
Accuracyat +25°C
±1% of range (45 Hz to 65 Hz)
Linearity10% to 100% of range
±0.2% of reading
Noise8 mV AC rms (30 A)
2 mV AC rms (300 A, 3000 A)
Frequency range10 Hz to 50 kHz (-3 dB)
Phase error< ±1° (45 Hz to 65 Hz)
±10° (at 20 kHz)
Position sensitivity (with cable > 25 mm from the coupling)

Position sensitivity: From 1% up to 3% of range with cable, depending on distance from the center (see figure left). Measurements closer than 25 mm from the coupling are typically greater than 3% of range.

External wire influence: 1% (-40 db) of external current >200 mm from head.

±2% of range
External fieldwith cable > 200 mm from the head
±1% of range
Power supply2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator
Temperature coefficient±0.08% of reading per °C
Working voltagesee safety standards section
600 V AC rms or DC
General Specifications
Head circumference610 mm (24in)
Head cable diameter14.3 mm (0.56in)
Head bend radius38.1 mm (1.5in)
Cable length (head to electronics)2 m (6.56 ft)
Output connection0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter
Operating temperature range-20°C to +90°C (-4°F to 190°F) (head)
-20°C to +85°C (-4°F to 185°F) (electronics)
Strong temperature range-40°C to +105°C (-40°F to 221°F) (head)
-20°C to +85°C (-4°F to 185°F) (electronics)
Operating humidity15% to 85% (non-condensing)
Weight180 g (0.396 lb) (head)
190 g (0.419 lb) (electronics)
Safety standardsBS EN 61010-1: 2001
BS EN 61010-2-032: 2002
BS EN 61010-031: 2002
600 Vrms, Category III, Pollution Degree 2
Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz
EMC standardsEN 61326: 1998 +A1, A2, and A3
Head cable length (double insulated)610 mm or 914 mm, depending on model

Models: Fluke i3000 Flex AC Current Clamp, 4 Pack

Fluke i3000 Flex 4PK
Find a distributor
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 21.16ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.31ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.

Manuals + resources: Fluke i3000 Flex AC Current Clamp, 4 Pack