Key features

Equipped with new functionality

  • NEW – Now compatible with Fluke Connect mobile app and all Fluke FC enabled test tools with the included ir3000 FC infrared connector.
  • NEW – Let your team see what you see in an instant with ShareLive™ video call using the Fluke Connect mobile app and ir3000 FC wireless connector.
  • TrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred.
  • Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.
  • Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy.
  • Adjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event.
  • Large 50,000 count, 1/4 VGA dot matrix display with white backlight.
  • Logging function with expanded memory for unattended monitoring of signals over time. Using on-board TrendCapture users can graphically review logged readings without needing a PC. Store up to 15,000 recorded events.
  • Save multiple logging sessions before PC download is necessary.
  • Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current. Useful for measuring and comparing differences in motor winding resistance or contact resistance.
  • Low Pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment.
  • LoZ Volts. Low impedance voltage function for eliminating ghost voltages. Also recommended when testing for absence or presence of live power.
  • On board help screens for measurement functions. Unsure about a function - go to that function and press the "i" button.
  • Real time clock for automatic time stamping of saved readings.
  • Relative mode to remove test lead resistance from low ohms or capacitance measurements.
  • True-RMS AC voltage and current for accurate measurements on non-linear signals.
  • Measure up to 10 A (20 A for 30 seconds).
  • 100 mF capacitance range.
  • Peak capture to record transients as fast as 250 μs.
  • Premium test leads and alligator clips included.
  • Amp jack plugs included.
  • Optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks.
  • FlukeView forms enable you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents.
  • Limited lifetime warranty.

Product overview: Fluke 289/ir3000 FC Kit

Fluke Connect®

Learn more about Fluke Connect

Now compatible with Fluke Connect® Mobile App

Maximize productivity with the combined Fluke 289 and FlukeView® Forms Combo Kit. With built-in data logger and TrendCapture capability, the 289 helps you track down elusive, intermittent problems, monitoring equipment with any of its functions while you do other jobs. Using FlukeView Forms software allows you to overlay your logged data from six meters or six time periods to find cause and affect relationships or for condition monitoring. Turn your data into meaningful graphs and tables for a professional report or analyze individual readings or series of measurements.

The 289 is compatible with the Fluke ir3000 FC Infrared Connector, allowing you to share live measurements on your iOS or Android smart device with the Fluke Connect mobile app. The 289/FVF combo kit, which now includes the ir3000 FC Connector, gives you a practical and affordable approach to predictive maintenance.

Specifications: Fluke 289/ir3000 FC Kit

Specifications
FunctionRange and ResolutionBasic Accuracy
DC volts50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V0.025 %
AC volts0.4 % (True-RMS)
DC current500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A0.05 %
AC current0.6 % (True-RMS)
Temperature (excluding probe)-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F)1.0 %
Resistance500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ,5.0000 MΩ, 50.00 MΩ, 500.0 MΩ0.05 %
Capacitance1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF1.0 %
Frequency99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz0.005 % + 1
ConnectivityOptional infrared connector via Fluke ir3000 FC
 
General Specifications
Maximum voltage between any terminal and earth ground1000 V
Battery type6 AA alkaline batteries, NEDA 15A IECLR6
Battery life100 hours minimum, 200 hours in logging mode
TemperatureOperating: -20 °C to 55 °C; Storage: -40 °C to 60 °C
Relative humidity0 to 90 % (0 t 37 °C), 0 to 65 % (37 °C to 45 °C), 0 to 45 % (45 °C to 55 °C)
Electromagnetic compatibilityEMC EN61326-1
VibrationRandom vibration per MIL-PRF-28800F Class 2
Shock1 meter drop per IEC/EN 61010-1 3rd Edition
Size (HxWxL)22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in)
Weight870.9 g (28 oz)
Multiple on screen displaysYes
LoZYes
50 ohm rangeYes
Filter for measurements on motor drivesYes
True-RMS AC bandwidth100 kHz
dBV/dBmYes
DC mV resolution1 μV
Megohm rangeUp to 500 MΩ
Conductance50.00 nS
Continuity beeperYes
Temperature (°C and °F)-200 °C to 1350 °C
Battery/fuse accessYes/Yes
Elapse time clockYes
Time of day clockYes
Min-Max-AvgYes
FrequencyYes
Duty cycle/pulse widthYes
Info button on board helpYes
HoldYes
Isolated optical interfaceYes
Auto/touch holdYes
Reading memoryYes
Log to PCYes
On board logging with TrendCaptureYes
Logging memory up to15,000 readings
Wireless connectivity (optional)Yes

Models: Fluke 289/ir3000 FC Kit

FLK-289/FVF/IR3000
289 Multimeter With Software And Wireless Connectivity Kit
Find a distributor
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 190.49ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Rated 2 out of 5 by from Hope you have a CD-ROM I purchased this kit thinking it would have a license code to get the FlukeView Forms software included in it so that I could download it from somewhere as most modern laptops do not have a CD-ROM drive in them anymore. Instead it just came with the CD-ROM and no license code or anything. Without a CD-ROM there doesnt appear to be any way to get the software installed. I've emailed Fluke's technical support people several times and have gotten no reply.
Date published: 2021-01-27
Rated 4 out of 5 by from Seems like a good meter, data transfer is clunky. I purchased the Fluke 289 kit primarily for data logging over 24 hours. I have been able to achieve my goal, but not easily. 1st the instructions in the manual for logging data are incorrect, but I was able to see where the error was and I found the correct way to start logging the data. Next, I was hoping the Bluetooth adapter would allow for data transfer from a mobile devices, but it doesn’t. I seems it is for watching the meter or sharing the meter readings at a distance with others. Next, I hooked up the data transfer cable to my PC (there is no software for the Mac as far as I can tell). This resulted in a UART driver to load on my PC. Since my laptop has no CD/DVD drive (and many laptops/notebooks eliminated them many years ago) I could not load the file transfer software that came with the meter on a DVD. So I visited the web site and discovered that I could not download the software from there either. Fluke, do you really think your file transfer software is so desirable that you can’t just post a download link for your customers for fear someone will steal it? Anyway, after striking out here, I called customer support and that worked very well. The agent sent me a link to a shared file on the Microsoft OneDrive cloud storage service and I was able to download it. Pausing here for a moment. This process feels like it was developed in the 1990s and hasn’t changed in 30 years. I am a retired IT guy and even I found it to be unreasonably cumbersome. I can’t imagine how painful this must be for a regular person with average PC skills. Next I ran the application and I figured out how to both transfer the data to the application on my PC and how to export it to a CSV file. The latter is what I really wanted all along, so I can manipulate the data myself in Excel. When I imported the data from the CSV file to Excel, I realized that the meter readings included the units in the same cell as the numeric value of the reading. This is a pain for analyzing the data. Try adding “10 V AC” and “20 V AC”. Nope. So I had to format these cells as text and then extract the numeric value from the text and place it in a new column as a number. Standard database practices dictate that fields not be overloaded. One field should be used for each value or attribute. Given the evolution of capabilities in a simple mobile phone, light switch or coffee maker over the past 10 years, I think the data transfer capabilities of this meter are pretty archaic and overly complicated for the intended user. I still like the meter, but the documentation needs to be corrected and this data transfer process needs a fresh development effort. This should all be done over Bluetooth or wifi these days. Or even use something like digital cameras do ... where the device looks like a USB disk drive to the computer and the files can be easily copied. I guess I’d still recommend the meter because I trust the Fluke brand in terms of accuracy and overall capabilities, but if someone wanted to log data and analyze it on a regular basis, I’d likely shop a round to see if anyone does this in a more modern and user friendly manner.
Date published: 2020-09-05
Rated 2 out of 5 by from Download 289 Memory Zero success in being able to use the IR3000 and Fluke app to download the stored series of readings on the 298. Searched Google, YouTube and called Fluke - with no success. Not a useful tool if all I can do is see the meter display on my phone. How do I get my 1400 data points into a spreadsheet so I can do some analysis?
Date published: 2019-12-05
Rated 3 out of 5 by from Great Meter - Poor Documentation I just received my new Fluke 289 Kit today and was very disappointed that there was no printed User Manual. The manual comes on a CD; I suppose they expect me to carry a computer around so I can refer to the manual! I docked Fluke two stars for being cheap and not providing a manual. I also gave an average rating for ease of use because without a manual it's not easy to use!
Date published: 2018-08-28
  • y_2024, m_11, d_4, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_4, tr_4
  • loc_en_US, sid_3840948797492, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.83ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.