Motors, drives, pumps, compressors

Name: Electronics Technician at major elevator manufacturer

Tools: Fluke MDA-550 Motor Drive Analyzer

Challenge: Quickly setting up and troubleshooting variable speed drives with an oscilloscope.

Solution: Fluke MDA-550 Motor Drive Analyzer provides clear diagrams of the proper setup, pre-defined test procedures and step-by-step instructions to save time and help streamline troubleshooting elevator motor drives.

One of the most prominent elevator companies in the world maintains more than 5,000 installations across Western Germany. These elevators are inside all types of business and commercial buildings, including office towers, hospitals, schools and high-rise apartment buildings. The workers and residents depend on the elevators every day. Downtime must be minimal.

The company employs scores of general purpose technicians on its maintenance team to perform preventative maintenance, troubleshoot and repair malfunctions, and even do post-mortems after failures to learn how they might be prevented in the future. In addition to the generalists, there is a group of five electronic specialists who cover the entire area. They primarily troubleshoot the increasingly sophisticated control systems, load weight devices and variable speed drives used to keep the elevators running smoothly.

Ups and downs of elevator maintenance

Motor drives in elevators are also called variable frequency drives (VFD), frequency converters or adjustable speed drives (ASD). They transform constant voltage from the main ac power supply into a voltage that varies to control motor torque and speed, ideal for motors that drive the cable or belt systems that move the elevators up and down.

Elevator Shaft Tech

One veteran electronics technician at the elevator company said he has typically used Fluke ScopeMeter® Test Tools (125B and 190) to troubleshoot drives. Recently, however, he switched to the new Fluke MDA-550 Motor Drive Analyzer. The technician is highly skilled with 25 years of experience, including electronics and telecommunications in the military and a degree from a technical school.

The new motor drive analyzer, he said, is great for both very skilled or less skilled technicians.

"It's a nice tool for everyone because you have guidance. And the interface takes you through the process of measuring," the elevator electronics technician said.

Troubleshooting made easy

The MDA combines a handheld oscilloscope with a multimeter and adds easy-to-read diagrams and step-by-step guidance through tests.

“The good thing about the MDA is that, for a skilled technician, you have the pictograms that show you how to set up the tool. That saves time on each testing,” he said. “The lower skilled technician can confirm the setup before they begin and move through the test, step by step.”

The MDA includes a walkthrough for all key tests, including:

  • Drive input
  • DC bus­­—ripple
  • Drive output
  • Motor input
  • Motor shaft voltage

“The MDA has all of these functions. It’s a great upgrade. For me it’s about simplifying my work. I can do all the same measurements that I can with the scopemeter, but it’s easier to use. You just pick the test and the settings are all ready to go.”

Fluke motor drive analyzers guide you through these tests and automate many of the needed calculations so you can have confidence in the results. Plus, you can save data to a report at nearly any test point, so you can have documentation to upload to a computerized maintenance management system (CMMS) or share with a colleague or consulting expert.

“I could do it with the oscilloscope using manual settings, but the MDA test is all set up and ready to use. When you’re doing a lot of measurements in one day, that saves a lot of time.”

F-MDA-550-01a

Confirming suspicions and fixing problems

In one recent service call, the electronics technician was troubleshooting a large elevator at a hospital. “Because of 14 years of work, the motor drive showed ripple on the load. They were ripples of the DC link. We thought it might have something to do with the aging of the capacitors. They tend to get drier and drier as they age.

“That’s a problem—the elevator will need more and more current because the capacitors will need more and more current. The result is that the capacitors get weaker and weaker, and you waste energy.

Using the MDA, I was able to go to the DC bus test and the DC ripple and quickly complete the test and confirm what we suspected,” he said.

They ended up changing out the whole bank of capacitors to fix the problem.

“I could do it with the oscilloscope using manual settings, but the MDA test is all set up and ready to use. When you’re doing a lot of measurements in one day, that saves a lot of time.”

Do you want to learn more?

Fill out our short Demo Request form and we will contact you to schedule your personal demo from a qualified Fluke engineer. You'll get a hands-on demonstration of the instrument in your workplace, focused on the measurements you need. You'll see how easy our instruments are to use, and receive training and advice on both the instrument and related accessories. So, if you buy, you're sure to select the instrument that's right for you, and get the most out of it!