Fluke 729 Automatic Pressure Calibrator | Fluke
English

Fluke 729 Automatic Pressure Calibrator

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.25ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Fluke 729 Automatic Pressure Calibrator - 1
  • Fluke 729 Automatic Pressure Calibrator - 2
  • Fluke 729 Automatic Pressure Calibrator

Key features

  • Automatic pressure generation and regulation to 300 psi
  • Configure procedures for pressure transmitters and switches
  • Measure, source, and simulate 4 to 20 mA signals
  • Troubleshoot and calibrate HART smart transmitters
  • Automatically document test results

Product overview: Fluke 729 Automatic Pressure Calibrator

Fluke Premium Care eligible

When you invest in your Fluke test tools, you want your money to go as far as possible. Fluke Premium Care is a paid offering that provides coverage above and beyond the original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair.

Learn more

Portable automatic pressure calibrator simplifies pressure calibration

The Fluke 729 Automatic Pressure Calibrator has been designed specifically with process technicians in mind to simplify the pres­sure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure can be a time-consuming task, but the 729 makes it easier than ever with an internal electric pump that provides automatic pressure generation and regulation in an in an easy-to-use, rugged, portable package.

The ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. Then, internal fine adjustment con­trol automatically stabilizes the pressure at the requested value.

The Fluke 729 can also automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure and the number of test points and tolerance level. The 729 does the rest.

Built-in HART communication capabilities enable HART transmitter mA adjustments, light HART configuration and the ability to adjust to applied 0% and 100% values.

Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data.

With three ranges to choose from, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), Fluke 729 Automatic Pressure Calibrators are designed to perform when and where you need them.

What's in the box:

  • Fluke 729 Automatic Pressure Calibrator
  • Li-Ion battery charger and adapters
  • Quick-Connect pressure fitting, hose and adapter starter kit
  • (1 pair) Stackable test leads
  • (1 set) AC280 SureGrip™ hook clips
  • (1 set) AC175 alligator clips
  • (1 pair) TP220 test probes (red, black)
  • USB communication cable
  • TPAK ToolPak™ Magnetic Meter Hanger Carrying case with shoulder strap and accessories pouch
  • DPCTrack2™ trial calibration management software
  • Traceable certificate of calibration
  • Quick Reference Guide
  • 3-year warranty

Specifications: Fluke 729 Automatic Pressure Calibrator

Pressure specification*
One-year specification 0.02% of full scale
Control specification 0.005% full scale minimum
*See manual for detailed specifications

 

Model
729 30G
Psi range, resolution-12.0000 to 30.0000 psi
Bar range, resolution-0.82737 to 2.06842 bar
kPa range, resolution-82.737 to 206.843 kPa
CommentNo wireless communication
729 150G
Psi range, resolution-12.000 to 150.000 psi
Bar range, resolution-0.8273 to 10.3421 bar
kPa range, resolution-82.73 to 1034.21 kPa
CommentNo wireless communication
729 300G
Psi range, resolution-12.000 to 300.000 psi
Bar range, resolution-0.8273 to 20.6843 bar
kPa range, resolution-82.73 to 2068.43 kPa
CommentNo wireless communication
729 30G FC
Psi range, resolution-12.0000 to 30.0000 psi
Bar range, resolution-0.82737 to 2.06842 bar
kPa range, resolution-82.737 to 206.843 kPa
CommentWireless communication for Fluke Connect
729 150G FC
Psi range, resolution-12.000 to 150.000 psi
Bar range, resolution-0.8273 to 10.3421 bar
kPa range, resolution-82.73 to 1034.21 kPa
CommentWireless communication for Fluke Connect
729 300G FC
Psi range, resolution-12.000 to 300.000 psi
Bar range, resolution-0.8273 to 20.6843 bar
kPa range, resolution-82.73 to 2068.43 kPa
CommentWireless communication for Fluke Connect
729CN 200K
Psi range, resolution-12.0000 to 30.0000 psi
Bar range, resolution-0.82737 to 2.06842 bar
kPa range, resolution-82.737 to 206.843 kPa
CommentFor China, no wireless communication
729CN 1M
Psi range, resolution-12.000 to 150.000 psi
Bar range, resolution-0.8273 to 10.3421 bar
kPa range, resolution-82.73 to 1034.21 kPa
CommentFor China, no wireless communication
729CN 2M
Psi range, resolution-12.000 to 300.000 psi
Bar range, resolution-0.8273 to 20.6843 bar
kPa range, resolution-82.73 to 2068.43 kPa
CommentFor China, no wireless communication
729CN 200K FC
Psi range, resolution-12.0000 to 30.0000 psi
Bar range, resolution-0.82737 to 2.06842 bar
kPa range, resolution-82.737 to 206.843 kPa
CommentFor China, wireless communication for Fluke Connect
729CN 1M FC
Psi range, resolution-12.000 to 150.000 psi
Bar range, resolution-0.8273 to 10.3421 bar
kPa range, resolution-82.73 to 1034.21 kPa
CommentFor China, wireless communication for Fluke Connect
729CN 2M FC
Psi range, resolution-12.000 to 300.000 psi
Bar range, resolution-0.8273 to 20.6843 bar
kPa range, resolution-82.73 to 2068.43 kPa
CommentFor China, wireless communication for Fluke Connect
729JP 200K
kPa range, resolution-82.737 to 206.843 kPa
CommentFor Japan, no wireless communication
729JP 1M
kPa range, resolution-82.73 to 1034.21 kPa
CommentFor Japan, 1 MPa range, no wireless communication
729JP 2M
kPa range, resolution-82.73 to 2068.43 kPa
CommentFor Japan, 2 MPa range, no wireless communication
729JP 200K FC
kPa range, resolution-82.737 to 206.843 kPa
CommentFor Japan, wireless communication for Fluke Connect
729JP 1M FC
kPa range, resolution-82.73 to 1034.21 kPa
CommentFor Japan, wireless communication for Fluke Connect
729JP 2M FC
kPa range, resolution-82.73 to 2068.43 kPa
CommentFor Japan, wireless communication for Fluke Connect

 

Electrical specification
All specifications are valid to 110% of range, except 24 mA source and simulate which are valid to 100% of range.
Ranges
mA measure, source and simulate0 mA to 24 mA
Volts dc measure0 V dc to 30 V dc
Resolution
mA dc source, simulate and measure1 μA
Voltage dc measurement1 mV
Accuracy0.01% ±2 LSD all ranges (at 23 °C ±5 °C)
Stability20 ppm of full scale /°C from -10 °C to +18 °C and 28 °C to +50 °C
mA simulate external voltage requirement12 V dc to 30 V dc
Loop compliance voltage24 V dc @ 20 mA
mA simulate external voltage requirement12 V dc to 30 V dc
Temperature measurement only/100 Ω Pt(385) RTD-50 °C to 150 °C (-58 °F to 302 °F)
Temperature resolution0.01 °C (0.01 °F)
Temperature accuracy±0.1 °C (0.2 °F) ±0.25 °C (±0.45 °F) combined uncertainty when using 720 RTD probe (optional accessory)
Drive capability1200 Ω without HART resistor, 950 Ω with internal HART resistor
Mechanical specification
Size (HxWxL)7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in)
Weight6.5 lbs., 2.95 kg
Ingress protectionIP54
Environmental specification
Operating temperature-10 °C to 50 °C for measurement, 0 °C to 50 °C for pressure control
Operating temperature with battery-10 °C to 40 °C
Battery will only charge to 40 °C
Storage temperature-40 °C to 60 °C
Operating altitude3000 m
Storage altitude13000 m
Wireless (729 FC only)
Radio frequency certificationFCC ID: T68-FBLE IC:6627A-FBLE
Wireless radio frequency range2412 MHz to 2462 MHz

Models: Fluke 729 Automatic Pressure Calibrator

FLK-729 30G
Fluke 729 Automatic Pressure Calibrator 30 psi, 2 bar range, no wireless communication
Buy it
FLK-729 150G
Fluke 729 Automatic Pressure Calibrator 150 psi, 10 bar range, no wireless communication
Buy it
FLK-729 300G
Fluke 729 Automatic Pressure Calibrator 300 psi, 20 bar range, no wireless communication
Buy it
FLK-729 30G FC
Fluke 729 Automatic Pressure Calibrator 30 psi, 2 bar range, includes wireless communication for Fluke Connect
Buy it
FLK-729 150G FC
Fluke 729 Automatic Pressure Calibrator 150 psi, 10 bar range, includes wireless communication for Fluke Connect
Buy it
FLK-729 300G FC
Fluke 729 Automatic Pressure Calibrator 300 psi, 20 bar range, includes wireless communication for Fluke Connect
Buy it
FLK-729CN 200K
Buy it
FLK-729CN 1M
Buy it
FLK-729CN 2M
Buy it
FLK-729CN 200K FC
Buy it
FLK-729CN 1M FC
Buy it
FLK-729CN 2M FC
Buy it
FLK-729PLUS 2M
Buy it
FLK-729PLUS 1M
Buy it
FLK-729PLUS 200K
Buy it
FPC1S-FLUKE729-1

Premium Care 1-Year Standard Plan for Fluke 729

Buy it

Includes:

  • Premium Care 1-Year Standard Plan
FPC3S-FLUKE729-1

Premium Care 3-Year Standard Plan for Fluke 729

Buy it

Includes:

  • Premium Care 3-Year Standard Plan
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 22.1ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.84ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat