Fluke T+ Canada Electrical Tester
Key features
- 3 forms of AC/DC voltage indication: light, sound, and vibration for added user protection and convenience
- Detect live voltage even when the batteries are dead
- Extra heavy-duty, replaceable test leads for more flexibility and durability
- CAT IV 600 V, CAT III 1000 V rated for added user protection
- Continuity beeper
- Bright LED flashlight for work in poorly lit areas
- GFCI Trip
- On/Off switchable beeper, selectable according to your environment
- Compliant with latest NFPA 70E recommendations*
- Replaceable test probes for added flexibility and convenience
- Convenient probe storage on the back
- Probe holder for easier testing
- Hazardous voltage warning light for added user protection
- Test lead strap included for better test lead management
- AC/DC Voltage: 12 V – 600 V on LED bar
- Auto-off saves battery power
- 2-year warranty
* When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment
Product overview: Fluke T+ Canada Electrical Tester
Safer than traditional solenoid testers and fully compliant with NFPA 70E*
The T+ Electrical Testers offer all the functionality that electricians look for in volt meters and voltage and continuity testers:
- Three ways to detect AC/DC voltage: light, sound, and vibration
- Added functionality of a GFCI trip and continuity beeper, plus the convenience of a built-in flashlight
Safer than traditional solenoid testers:
- Solid-state tester design
- CAT IV 600 V, CAT III 1000 V rated
- Complies with NFPA 70E*
The ruggedness and reliability that customers have come to expect from Fluke
* When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment.
Specifications: Fluke T+ Canada Electrical Tester
Specifications | ||
Temperature | Operating | -10°C to 55°C (14°F to 131°F) |
Storage | -30°C to 60°C (-22°F to 140°F) | |
Relative humidity | 90% | 0°C to 30°C (32°F to 86°F) |
75% | 30°C to 40°C (86°F to 104°F) | |
45% | 40°C to 50°C (104°F to 122°F) | |
Altitude | Operating | 2,000 m (approx. 6,561.6 ft) |
Storage | 10,000 m (approx. 32,808.4 ft) | |
Battery type/life | AAA (2); 40 hours | |
Shock, vibration | Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument | |
Safety | ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV Compliance to NFPA 70E1 | |
AC bandwidth | 45 Hz to 66 Hz | |
Maximum working voltage | 1000 V AC/DC | |
Maximum measurable voltage | 600 V AC/DC | |
Duty cycle | Indefinitely for voltages up to 240 V | |
For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off | ||
For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s | ||
Voltage hazard LED | LEDs turn on at voltages > 30 V AC/DC ± 35% | |
LED voltage indication levels | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 347 V, 480 V, 600 V | |
LEDs | LEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100% | |
LCD resolution | 0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V | |
GFCI test current | 100 V - 150 V @ 6 mA - 9 mA AC, 150 V - 240 V < 12 mA | |
Standard input test current | < 5 mA | |
Size (H x W x L) | 1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm ) | |
Weight | 9.9 oz (0.28 kg) | |
1. When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment. |
Models: Fluke T+ Canada Electrical Tester
Fluke T+ CAN
Fluke T+ Canada Electrical Tester
Includes:
- User manual
- Test lead wrap
- TP2 test probes
This model is only available in Canada