Fluke T6-600 Electrical Voltage, Current and Continuity Tester | Fluke
English

Fluke T6-600 Electrical Tester

Fluke T6-600 Electrical Tester is rated 2.9 out of 5 by 9.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 23.39ms
  • REVIEWS, PRODUCT
  • Fluke T6-600 Electrical Tester - 1
  • Fluke T6-600 Electrical Tester - 2
  • Fluke T6-600 Electrical Tester
  • Fluke T6-600 Electrical Tester - 4

Key features

  • Measure AC voltage and current without touching a live wire
  • Troubleshoot with all power supply measurements at-a-glance
  • See AC voltage and current values without test leads

Product overview: Fluke T6-600 Electrical Tester

Measure voltage … without test leads

Working in cramped electrical boxes and trying to find a safe metallic contact points is often challenging. The Fluke T6-600 Electrical Tester with FieldSense™ technology, lets you quickly and safely take measurements by sliding the open fork over a conductor, without the need for test leads. The T6-600 works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening

How FieldSense™ technology works

FieldSense™ technology is a breakthrough in how voltage is measured. Other open fork testers detect a magnetic field to show AC current. FieldSense™ technology detects an electrical field, which interacts with a reference signal created by the T6 tester, which shows the measurement value on the tester’s display.

Tips on using FieldSense technology

  • Do not hold or touch wire you are testing during a measurement.
  • Use the black probe to make the ground connection if you are wearing gloves, insulated footwear or standing on an insulated ladder

Measurement versatility

The electrical tester offers a variety of measurement options giving you an all-in-one troubleshooting tool. Measure true rms voltage and current from 0 to 200 A AC or 1 to 600 V AC or DC. You can also gather resistance measurement from 1 Ω to 2000 Ω. With the easy-to-read backlit display, you can keep see your work in dark environments and keep your most recent measurement on the screen with the HOLD button for easy viewing. The T6-600 also accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation.

FieldSense tools

Learn how to use the T6
Download the Quick Reference Guide
Download the T6 "How-To" Demonstration Guide
Read the FieldSense Proving Unit Demonstration Guide

FieldSense tools

T6 Electrical Tester Helps Team at Cutting Edge Cancer Research Center

T6 Awards

PTIA 2018 Awards Winner

2017 NECA Showstopper H18 Innovation Awards Winner

Dealer Design Award 2018

What's in the box:

  • Fluke T6-600 Electrical Tester
  • Attached test leads with removable 4 mm probe caps
  • Quick Reference Guide

Specifications: Fluke T6-600 Electrical Tester

Measurement Specifications
FunctionRequires test leadsRangeResolutionAccuracy[1]
FieldSense
ac voltage true-rms
No600 V1 V±(3% + 3 counts) 45 Hz - 66 Hz[2] [3]
FieldSense
ac current true-rms
No200.0 A0.1 A±(3% + 3 counts) 45 Hz - 66 Hz
Volts ac true-rmsYes600 V1 V±(1.5% + 2 counts) 45 Hz - 66 Hz
Volts dcYes600 V1 V±(1% + 2 counts)
ResistanceYes2000 Ω1 Ω±(1% + 2 counts)
Safety 600 V CAT III

Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.

Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.

Accuracy[3]: FieldSense is specified from 16 V to 100 % of range.

General Specifications
Calibration1-year calibration cycle
Dimensions61.1 x 259.3 x 43.8 mm
Jaw opening17.8 mm
Weight0.35 kg (0.78 lb)
TemperatureOperating-10 °C to +50 °C (14 °F to 122 °F)
Storage-30 °C to +60 °C (-22 °F to +140 °F)
AltitudeOperating2,000 m (6,562 feet)
Storage10,000 m (32,808 feet)
Relative Humidity0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)
0% to 75%, 30°C to 40 °C (86 °F to 104 °F)
0% to 45%, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense
Temperature coefficient0.1 x (specified accuracy) / °C for <18°C or >28 °C
(< 64.4 °F or > 82.4 °F)
SafetyIEC/EN 61010-1: Pollution Degree 2
Electromagnetic EnvironmentIEC/EN 61326-1: Portable

Models: Fluke T6-600 Electrical Tester

T6-600 Electrical Tester
Fluke T6-600 Electrical Tester
Buy it

Includes:

  • Attached test leads with removable 4 mm probe caps, user documentation

can this meter be used to read PWM Voltage Output from a VFD?

Asked by: Sttim
  • y_2024, m_11, d_4, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestions, tq_1
  • loc_en_US, sid_3739311177780, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 23.22ms
  • QUESTIONS, PRODUCT
Rated 4 out of 5 by from Thumbs up It's a quality product and is well thought out. The leads are of good quality, although the orienation makes the devise hard to put in a bag. The back lit screen is nice.
Date published: 2024-05-04
Rated 3 out of 5 by from T6-600 Field sense is not completely accurate/ basically just a more accurate non contact voltage detector
Date published: 2021-05-30
Rated 2 out of 5 by from Compact for novices Fieldsense rarely works and eventually the clip wears out. Compact design would make this great if the leads weren't tied in so inconveniently keeping you concerned about damaging them. Reads are decent but the jaw is too small for anything above basic wiring and the length of the wire placement makes it extremely difficult to place properly. Adequate for a 1st year who's main goal is to verify basic ranges. Soley purchased to be a compact tester to compliment my 1587 fc.
Date published: 2021-05-15
Rated 1 out of 5 by from Gimmicky Rubbish. Get the T5 instead. Purchased to replace my T5. The single probe voltage measurement "feature" only works when your body is very well grounded and thus demands unsafe meter handling to work, even then the results are inaccurate. Field sense is a total joke, on the occasion that it actually works the results are wildly inaccurate to the point of being unusable. Its verydisappointing that Fluke even released this meter and it really should be subject to a recall. However despite that, the traditional functions do work well, the only reasons to concider a T6 over a T5 is the higher current limit and larger jaw. But its absolutely not worth the extra cost.
Date published: 2021-04-12
Rated 1 out of 5 by from Extremely Frustrating I've owned the T-6 1000v and 600v. The non detachable leads and the material they are made of is infuriating. They are twisted and tangled and can't be untwisted. When working in a live panel or switch gear this is a major issue when I my leads pull and flip my meter so I can't see the screen or knocks it off a surface; which is the last thing you want to deal with while shoulder deep in live gear. The $40+ magnetic hanger kit even even worse when your meter flips belly up so you can see the display. FIX THE LEADS! Fieldsence feature is also noticably inaccurate.
Date published: 2020-09-24
Rated 1 out of 5 by from Do not buy this product By far the worst meter I’ve ever owned. I payed around $400 nz dollars for this paper weight. THE FIELDSENSE AND AMP READINGS ARE INCREDIBLY UNRELIABLE. Waste of money
Date published: 2020-06-16
Rated 5 out of 5 by from Special power tools for critical areas This product is very flexible for use in critical areas, with high protection and reliability, I recommend it
Date published: 2019-11-12
  • y_2024, m_11, d_4, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_2, tr_7
  • loc_en_US, sid_3739311177780, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.52ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat