Fluke 15B+ Digital Multimeter | Fluke
English

Fluke 15B+ Digital Multimeter

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.04ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Fluke 15Bplus Digital Multimeter 1
  • Fluke 15Bplus Digital Multimeter 2
  • Fluke 15Bplus Digital Multimeter 2

Key features

  • 600 V Cat III safety rating
  • AC/DC voltage measurement up to 1000V
  • AC/DC current measurement up to 10A
  • Measures voltage, resistance, continuity, capacitance
  • Diode test, data hold
  • Large easy-to-read display with bright white backlight

Product overview: Fluke 15B+ Digital Multimeter

Fluke quality is always within your reach

Unlock professional-grade precision, durability, and safety with the Fluke 15B+ Digital Multimeter. The Fluke 15B+ packs all the core functionality you need in a digital multimeter into a portable, rugged form tool that’s easy-to-use with one hand, even with gloves on. From AC/DC voltage and current measurements up to 1000V and 10A, to comprehensive capabilities including resistance, and capacitance checks, the 15B+ is your go-to for troubleshooting a wide array of electrical issues.

The CAT III 600V safety rating provides peace of mind for everything from routine checks on electrical equipment and appliances, to checking voltage levels at power outlets or switches, to diagnosing issues with circuits. Ideal for both DIY enthusiasts and early career electricians looking to streamline their toolkit, the Fluke 15B+ is a reliable and versatile addition to your toolkit.

What's in the box:

  • Fluke 15B+ Digital Multimeter
  • Fluke TL75 Test Leads
  • 2 AA Batteries

Specifications: Fluke 15B+ Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

FunctionRangeResolutionAccuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts400.0 mV0.1 mV3.0% + 3
DC millivolts400.0 mV0.1 mV1.0% + 10
Diode test22.000 V0.001 V10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance340.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current μA400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
DC current mA40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
BacklightYes
1AC volts are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
FunctionOverload protectionInput impedance (Nominal)Common mode rejection ratioNormal mode rejection ratio
AC volts1000 V 1>10 MΩ <100 pF>60 dB at dc,
50 Hz or 60 Hz
-
AC millivolts400 mV>1MΩ, <100 pF>80 dB at 50 Hz or 60 Hz-
DC volts1000 V 1>10 MΩ <100 pF>100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts400 mV>1MΩ, <100 pF>80 dB at 50 Hz or 60 Hz-
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground1000 V
Display (LCD)4000 counts, updates 3/sec
Battery type2 AA, NEDA 15A, IEC LR6
Battery life500 hours minimum
Temperature
Operating0 °C to 40 °C
Storage-30 °C to 60 °C
Relative humidity
Operating humidityNon-condensing (<10°C)
≤90% RH at 10 °C to 30 °C;
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C;
≤70% RH at 30 °C to 40 °C
Altitude
Operating2000 m
Storage12,000 m
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L)183 x 91 x 49.5 mm
Weight455 g
IP ratingIP 40
SafetyIEC 61010-1, IEC61010-2-030 CAT III 600 V, Pollution Degree 2
Electromagnetic CompatibilityIEC 61326-1: Portable EMC Environment
Class A equipment (industrial broadcasting & communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.

Models: Fluke 15B+ Digital Multimeter

Fluke 15B+
Fluke 15B+ Digital Multimeter
Buy it
Includes:
  • TL75 test leads with two caps
  • 2 AA batteries
  • User’s manual 
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 66.11ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.64ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat