Fluke 289 True-RMS Industrial Data Logging Multimeter | Fluke
English

Fluke 289 True-RMS Data Logging Multimeter

Fluke 289 True-RMS Data Logging Multimeter is rated 4.4 out of 5 by 45.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 23.12ms
  • REVIEWS, PRODUCT
  • Fluke 289 True-RMS Industrial Logging Multimeter
  • Fluke 289 True-RMS Industrial Logging Multimeter
  • Fluke 805 FC Vibration Meter
  • Fluke 289 True-RMS Industrial Logging Multimeter

Key features

  • Share results with your team using ShareLive™ video call (requires ir3000 FC wireless connector [sold separately] and no-cost Fluke Connect mobile app).
  • TrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred.
  • Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.
  • Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy.
  • Low Pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment.
  • LoZ Volts. Low impedance voltage function for eliminating ghost voltages. Also recommended when testing for absence or presence of live power.
  • Adjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event.
  • Large 50,000 count, 1/4 VGA dot matrix display with white backlight.
  • Measure up to 10 A (20 A for 30 seconds).
  • 100 mF capacitance range.

Product overview: Fluke 289 True-RMS Data Logging Multimeter

Fluke 289 True-RMS Logging Multimeter helps you find little problems before they become big ones

The Fluke 289 is the next generation high performance industrial logging multimeter. This Fluke Connect-compatible DMM is designed to solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment. Let the 289 be your watchdog for systems or processes while you are off doing other jobs. It provides the ability to log data and graphically review up 10,000 recorded events and logged readings with on-board TrendCapture. Zoom on trend provides a 14x zoom to view and analyze data—without needing a PC.

Because the 289 is Fluke Connect-compatible you can set it up with the ir3000 FC wireless connector (sold separately) to communicate with your iOS and Android smart devices through the Fluke Connect mobile app and monitor readings from a remote location. Or you can share readings with your team in an instant anytime, from anywhere with ShareLive™ video call. It can help you solve problems faster and minimize downtime.

Other useful features:

  • Provides up to a 14x zoom to view and analyze TrendCapture data in depth
  • Includes a selectable AC filter (smoothing mode) to help display a steadier reading when the input signal is changing rapidly or noisy.
  • Offers adjustable recording and auto hold thresholds to specify a percentage change in the readings that begins a new event
  • Features a large 50,000 count, 1/4 VGA dot matrix display with white backlight
  • Stores up to 15,000 recorded events so you can save multiple logging sessions before PC download is necessary
  • Provides two-terminal 50 ohm range with 1 milliohm resolution, 10 mA source current, for measuring and comparing differences in motor winding resistance or contact resistance
  • Includes low pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment.
  • Provides LoZ Volts, a low impedance voltage function for eliminating ghost voltages Recommended when testing for absence or presence of live power
  • Features on-board help screens for measurement functions
  • Includes a real-time clock to automatically time stamp saved readings
  • Offers relative mode to remove test lead resistance from low ohms or capacitance measurements
  • Provides True-RMS AC voltage and current for accurate measurements on non-linear signals
  • Measures up to 10 A (20 A for 30 seconds)
  • Provides up to 100 mF capacitance range
  • Records transients as fast as 250 μs with peak capture
  • Includes premium test leads, alligator clips, and amp jack plugs
  • Offers optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks
  • Works with optional FlukeView forms to enable you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents.
  • Includes a limited lifetime warranty.

What's in the box:

  • 289 True-RMS Industrial Logging Multimeter
  • (1 pair) TL71 Test Leads
  • AC175 Alligator Clips
  • 6 AA batteries (installed)
  • Quick reference guide
*Requires Fluke ir3000 FC Infrared Connector for Fluke Connect communication

Specifications: Fluke 289 True-RMS Data Logging Multimeter

Specifications
Function
DC voltsRange / resolution50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy0.025%
AC voltsRange / resolution50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy0.4% (True-RMS)
DC currentRange / resolution500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy0.05%
AC currentRange / resolution500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy0.6% (True-RMS)
Temperature (excluding probe)Range / resolution-200.0°C to 1350.0°C (-328.0°F to 2462.0°F)
Basic accuracy1.0%
ResistanceRange / resolution50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
Basic accuracy0.05%
CapacitanceRange / resolution1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF
Basic accuracy1.0%
FrequencyRange / resolution99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Basic accuracy0.005%
ConnectivityOptional infrared connector via Fluke ir3000 FC
General Specifications
Maximum voltage between any terminal and earth ground1000 V
Battery type6 AA alkaline batteries, IECLR6
Battery life100 hours minimum, 200 hours in logging mode
TemperatureOperating-20°C to 55°C
Storage-40°C to 60°C
Relative humidity0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C)
Electromagnetic compatibilityEMC EN61326–1
VibrationRandom vibration per MIL-PRF-28800F Class 2
Shock1 meter drop per IEC/EN 61010–1 3rd Edition
Size (H x W x L)22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in)
Weight870.9 g (28 oz)
Multiple on screen displaysYes
True-RMS AC bandwidth100 kHz
dBV/dBmYes
DC mV resolution1 μV
Megohm rangeUp to 500 MΩ
Conductance50.00 nS
Continuity beeperYes
Battery/fuse accessYes/Yes
Elapse time clockYes
Time of day clockYes
Min-max-avgYes
Duty cycleYes
Pulse widthYes
Isolated optical interfaceYes
Auto/touch holdYes
Reading memoryYes
Log to PCYes
Interval/event loggingYes
Logging memoryUp to 15,000 readings
Wireless connectivity (optional)Yes

Models: Fluke 289 True-RMS Data Logging Multimeter

Fluke 289
Fluke 289 True-RMS Industrial Logging Multimeter
Buy it

Includes:

  • 289 True-RMS Industrial Logging Multimeter
  • TL71 Test Leads
  • AC175 Alligator Clips
  • Batteries – 6 AA Installed

Requires Fluke ir3000 FC Infrared Connector for Fluke Connect communication

Is the Fluke 289 the replacement for the Fluke 45?

Asked by: HarryPC
The main difference is the Fluke 45 was a bench top unit and the Fluke 289 is hand held. Functionally the Fluke 45 had a 5.5 dual display. If you are good with going portable, then the Fluke 289 is a good pick.
Answered by: FlukeCorporation
Date published: 2024-06-29

Can i use this 289 multimeter with one of the accessory clamps (400 or 410) to measure motor inrush current?

Asked by: Nicko
It is recommended to use a clamp meter or meter with an inrush function. Response time is based on the meter and that is about a 200ms sample rate. You can talk to a Fluke sales expert about selecting the right product for your needs at 877-864-5880.
Answered by: FlukeCorporation
Date published: 2024-03-28
  • y_2024, m_11, d_2, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_3739275427892, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 110.21ms
  • QUESTIONS, PRODUCT
Rated 1 out of 5 by from Horrible experience with promo I ordered a multimeter and spent the extra money to take advantage of the tier 2 promo that they were advertising.. little did i know, the items for tier 2 were out of stock so i ordered the more expensive multimeter for nothing.. not only that, i never received my promo gift either even after sending receipts of invoice and all as asked.. Whoever Fluke partners with for their promo is an embarrassment to the company and has assured me that i will never spend another dollar with them
Date published: 2023-11-16
Rated 3 out of 5 by from Accurate but heavy and battery terminals weak Pros: - Accurate - Used as calibrated reference in our lab Cons - Relatively heavy. Best for table use, uncomfortable for field use - Conventional batteries (not rechargeable) - Need to separately purchase cable and software to export data - Battery terminal tabs snapped off
Date published: 2022-06-12
Rated 5 out of 5 by from A meter with most everything in one unit. I am really happy with this meter. I needed a meter with a very fast response time to test if PLC circuits were actually dropping to zero during transitions. I need the LoZ function to make sure the voltage is real. I regularly use the large display to show max/min/average in real time, or voltage and frequency, all at the same time. I can’t stress enough how nice it is to have a meter with more than one display line. I often use the AC & DC simultaneous display, which is very helpful for probing circuits when the voltage type is unknown or changing. I can trust the accuracy and safety. The Lo-ohms feature is a bonus to get very accurate and relative readings. For so many features it’s very easy to use and navigate; the menu system is intuitive and the whole meter is well thought out. The only disappointments are the physical quality control. The USB interface doesn’t fit right and pops off when any movement or bump occurs (Fluke has sent a replacement which has the same problem.) The Bluetooth device fits securely so I dont think the issue is the meter itself, but the FVF cable. The kickstand isn’t molded quite right and doesn’t stay closed. Just a nitpick, but the serial # sticker is illegible and put on crooked. But, the unit works, the screen is clean, it does more than most anyone else’s meter I’ve come across, and does it well.
Date published: 2022-02-21
Rated 5 out of 5 by from Awesome Mutimeter This is a great very accurate meter with a lot of thought
Date published: 2021-05-30
Rated 5 out of 5 by from fluke forever!!! i've been a fluke user since 1980. have about 10 devices & love em all.
Date published: 2021-05-30
Rated 4 out of 5 by from Mostly very good, but diode test is dangerous I really like the datalogging and min/max/avg functions, but the diode test function can destroy sensitive low voltage LEDs and GaAs detector diodes. Yes, 5.36V of reverse bias can and will do this!
Date published: 2020-08-21
Rated 5 out of 5 by from Excellent meter I had this meter for over a year. All I seen here on the review is people putting this meter down. There is nothing at all wrong with this meter. In fact this meter is the best I ever used and is spot on with its readings, also fast. So all I can say to the people on here, is you should learn how to use a multimeter, maybe you should buy a more basic model if this is to advance for you. I do lots of electronics and power supply repairs, and this meter is top and a full 10 out of 10 for everything. Also people putting the kick stand down? There nothing wrong with it. Also about dropping it and not being robust? Who in their right mind would want to drop an expensive meter like this? Fluke you don’t an amazing job and made a fantastic meter. Good work.
Date published: 2020-07-24
Rated 4 out of 5 by from Excellent Troubleshooting Tool Anyone who works in electronics can appreciate a tool that can babysit a device, power supply or line voltages. This meter is the ultimate. It has one of the fastest continuity modes available- very important for quick checking connector issues. I traded my Fluke 8846A bench meter for this one due to measurement speed issues-trading a couple digits of resolution for a more portable faster meter. The trend plots allow you to set the meter up and capture very fast intermittants leaving no doubt as to a component reliability. The display could be redesigned with slightly larger fonts but I have poorer vision. The boot up time of 2 seconds does not bother me as this has a fairly sophisticated processor on board. Would be nice if Fluke included a cable and software for the price of the stand alone kit. Great meter, would buy again. Earl
Date published: 2019-06-03
  • y_2024, m_11, d_2, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_5, tr_40
  • loc_en_US, sid_3739275427892, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.09ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.

Manuals + resources: Fluke 289 True-RMS Data Logging Multimeter

Chat with ourFluke assistant
Clear Chat