Ti95 Fluke Connect FCA Kit
Key features
The Fluke Ti95 Infrared Camera offers:
- The only wireless industrial infrared camera in its price class¹ – take advantage of the benefits of Fluke Connect® by seamlessly gathering and sharing inspection results instantly
- Superior image quality, up to 23% better spatial resolution than other competitive models in this price class¹
- 80x80 resolution
- Removable 8 GB SD Memory Card
- 8 GB Fluke Connect® wireless SD Card
- Find potential problems faster and easier with IR-Fusion® picture-in-picture mode
- 2 megapixel built-in digital camera
- Large 3.5 inch LCD - 32% larger screen than other competitive models lets you clearly see what you are measuring
- Smart Battery System - Lithium ion smart battery pack with five-segment LED display to show charge level
- Rugged, lightweight, point–and–shoot infrared camera
The Fluke 3000 FC Series Wireless Multimeter offers:
- AC and DC voltage measurements to 1000V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX recording
- CAT III 1000 V, Cat IV 600 V; IP54
The Fluke a3001 FC Wireless iFlex™ AC Current Module offers:
- One (1) true-RMS flexible current meter
- One (1) iFlex i2500-10 flexible current probe
- Measure up to 2500 A AC
- Use as a standalone meter or as part of the system
- Logging function for recording and saving up to 65,000 readings
- Inrush function
- Magnetic hanging strap
¹ Class is defined as an industrial handheld infrared camera in the same price range based on MSRP as of May 1, 2014.
Product overview: Ti95 Fluke Connect FCA Kit
See How It Works
Fluke Connect FAQs
Troubleshooting just got easier with the Ti95 Fluke Connect FCA Kit with Ti95 Infrared Camera, 3000 FC DMM, and a3001 FC iFlex® Module. This kit features the only wireless industrial infrared camera in its price class¹, the Ti95. Safely capture AC current measurements with your a3001 FC iFlex Module from up to 20 meters away on the 3000 FC DMM, while simultaneously conducting an infrared inspection with your Ti95 infrared camera. Upload your measurement data to the Cloud via your smart phone and you can analyze and share your inspection results for each piece of equipment from anywhere, with any team member, at any time - only with Fluke Connect™.
¹ Class is defined as an industrial handheld infrared camera in the same price range based on MSRP as of May 1, 2014.
Specifications: Ti95 Fluke Connect FCA Kit
Fluke Ti95 Infrared Camera
Key Features | |
IFOV (spatial resolution) | 5.6 mRad |
Resolution | 80 x 80 (6,400 pixels) |
Field of view | 26° H x 26° V |
Wireless connectivity | Yes |
Fluke Connect™ app compatible | Yes, with included wireless SD card (where available) |
IR-Fusion® technology | PIP (46 cm (18 in) and beyond) |
Focus system | Fixed focus 46 cm (18 in) and beyond |
Ruggedized display | 3.5 inch diagonal (portrait format) |
Rugged, ergonomic design for one-handed use | Yes |
Thermal sensitivity (NETD) | ≤ 0.10°C at 30°C target temp (100 mK) |
Temperature measurement range (not calibrated below -10°C) | -20°C to +250°C (-4°F to +482°F) |
Level and span | Smooth auto and manual scaling |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (in manual mode) | 2.5°C |
Minimum span (in auto mode) | 5°C |
Built-in digital camera (visible light) | 2 megapixel industrial performance |
Frame rate | 9 Hz only |
Data Storage and Image Capture | |
Extensive SD memory system | Removable 8 GB SD memory card and 8 GB wireless SD card (where available) |
Direct download via USB-to-PC connection | |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
File formats image | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) |
No analysis software required for non-radiometric (.bmp, .jpg) files | |
Memory review | Thumbnail view navigation and review selection |
Software | SmartView® software, Fluke Connect™, and SmartView® Mobile app - full analysis and reporting software |
Export file formats with SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Battery | |
Batteries (field-replaceable, rechargeable) | One lithium ion smart battery pack with five-segment LED display to show charge level |
Battery life | Four+ hours continuous use per battery pack (assumes 50% brightness of LCD and average usage) |
Battery charge time | 2.5 hours to full charge |
AC battery charging system | In-imager charging. AC mains adapters included in 9 Hz versions. Optional two-bay AC battery charger (110 VAC to 220 VAC, 50/60 Hz) or optional 12 V automotive charging adapter. |
AC operation | AC operation with included power supply (110 VAC to 220 VAC, 50/60 Hz). AC mains adapters included. |
Power saving | User selectable sleep and power off modes |
Temperature Measurement | |
Accuracy | ±2°C or 2% (at 25°C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both number and table) |
On-screen reflected background temperature compensation | Yes |
Color Palettes | |
Standard palettes | 6: Ironbow, blue-red, high-contrast, amber, hot metal, grayscale |
General Specifications | |
Infrared spectral band | 9 μm to 15 μm (long wave) |
Operating temperature | -10°C to +50°C (14°F to 122°F) |
Storage temperature | -20°C to +50°C (-4°F to 122°F) |
Relative humidity | 10% to 95%, non-condensing |
Center-point temperature measurement | Yes |
Spot markers | Hot and cold spot markers |
Center box (MIN-MAX-AVG) | Fixed-size measurement box with MIN-MAX-AVG temp |
Safety standards | CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 |
Electromagnetic compatibility | EN 61326-1:2006 IEC 61326-1:2005 |
C Tick | IEC/EN 61326-1 |
US FCC | EN61326-1; FCC Part 5 |
Vibration | 2G, IEC 68-2-6 |
Shock | 25G, IEC 68-2-29 |
Drop | Engineered to withstand 2 meter (6.5 feet) drop |
Size (H x W x L) | 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) |
Weight (battery included) | 0.726 kg (1.6 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
Fluke 3000 FC Wireless Multimeter
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications | |||||
AC Voltage | |||||
Range ¹ / Resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | ||||
Accuracy 2 3 4 | 45 Hz to 500 Hz | 1.0 % + 3 | |||
500 Hz to 1 kHz | 2.0% + 3 | ||||
1. All AC voltage ranges are specified from 1 % of range to 100 % of range. 2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3. 4. Do not exceed 107 V-Hz. | |||||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |||||
Function | |||||
mV | Range / Resolution | 600.0 mV / 0.1 mV | |||
Accuracy | 0.09% + 2 | ||||
V | Range / Resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | |||
Accuracy | 0.09% + 2 0.15% + 2 | ||||
))) | Range / Resolution | 600 Ω / 1 Ω | |||
Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | ||||
Ω | Range / Resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ | |||
Accuracy | 0.5% + 2 0.5% + 1 1.5% + 3 | ||||
Diode test | Range / Resolution | 2.000 V / 0.001 V | |||
Accuracy | 1% + 2 | ||||
µF | Range / Resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF1 / 1 μF | |||
Accuracy | 1.2% + 2 10% typical | ||||
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | |||||
AC and DC Current | |||||
Function | |||||
mA AC (45 Hz to 1 kHz) | Range 1 / Resolution | 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA | |||
Accuracy | 1.5% + 3 | ||||
mA DC 2 | Range 1 / Resolution | 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA | |||
Accuracy | 0.5% + 3 | ||||
1. All AC current ranges are specified from 5 % of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA. 3. 400.0 mA accuracy specified up to 600 mA overload. | |||||
Frequency | |||||
Range / Resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz | ||||
Accuracy 1 | 0.1% + 1 | ||||
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | |||||
Input Characteristics | |||||
Function | Overload protection | Input impedance (nominal) | Common mode rejection ratio (1 kΩ unbalance) | Normal mode rejection | |
1100 Vrms | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | ||
1100 Vrms | > 10 MΩ < 100 pF | > 60 dB, DC to 60 Hz | > 60 dB at 50 Hz or 60 Hz | ||
1100 Vrms | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | ||
Open circuit test voltage | Full scale voltage | Typical short circuit current | |||
To 6 MΩ | 50 MΩ | Typical short circuit current | |||
1100 Vrms | < 2.7 VDC | < 0.7 VDC | < 0.9 VDC | < 350 mA | |
1100 Vrms | < 2.7 VDC | 2.000 VDC | < 1.1 mA | ||
mA Function | |||||
Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | ||||
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | ||||
MIN/MAX Recording Accuracy | |||||
DC functions | The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration. | ||||
AC functions | The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration. | ||||
General Specifications | |||||
Maximum voltage between any terminal and earth ground | 1000 VDC or AC rms | ||||
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | ||||
Display (LCD) | Update rate | 4/sec | |||
Volts, amps, ohms | 6000 counts | ||||
Frequency | 10,000 counts | ||||
Capacitance | 1,000 counts | ||||
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | ||||
Battery life | 250 hours minimum | ||||
RF communications | 2.4 GHZ ISM Band | ||||
RF communication range | Open air, unobstructed | Up to 20 m | |||
Obstructed, sheetrock wall | Up to 6.5 m | ||||
Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5 m | ||||
Temperature | Operating | -10°C to 50°C | |||
Storage | -40°C to 60°C | ||||
Temperature coefficient | 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | ||||
Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) | ||||
Altitude | Operating | 2,000 m | |||
Storage | 12,000 m | ||||
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE | ||||
Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 | ||||
Certifications | CSA, FCC, CE | ||||
Ingress Protection (IP) rating | IP54 | ||||
Pollution Degree | 2 | ||||
Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||||
Weight | 340 g (12 oz) | ||||
Warranty | Three years | ||||
Not compatible with Fluke CNX test tools |
Fluke a3001 FC Wireless iFlex® AC Current Module
Specifications | ||
Range | 0.5 A to 2500 A AC | |
Resolution | 0.1 A | |
Accuracy | 3% ±5 digits (5 Hz to 500 Hz) | |
Crest factor (50 Hz / 60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A add 2% for C.F. > 2 | |
LCD w/backlight | 3½ digits | |
Log rate/interval | 1 sec minimum/adjustable by PC or front panel | |
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |
Battery life | 400 hours | |
Memory | Record up to 65,000 readings | |
RF communications | 2.4 GHZ ISM Band | |
RF communication range | Open air, unobstructed | Up to 20 m |
Obstructed, sheetrock wall | Up to 6.5 m | |
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Temperature coefficient | Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | |
Operating humidity | 90% at 35°C 75% at 40°C 45% at 50°C | |
Altitude | Operating | 2,000 m |
Storage | 12,000 m | |
EMC | EN 61326-1:2006 | |
Safety compliance | IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition | |
Safety rating | CAT IV 600 V, CAT III 1000 V | |
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |
Ingress Protection (IP) rating | IP42 | |
Pollution Degree | 2 | |
Jaw opening | 25.4 cm (10 in) coil | |
Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |
Weight | .22 kg (8 oz) | |
Warranty | Three years | |
Not compatible with Fluke CNX test tools |
Models: Ti95 Fluke Connect FCA Kit
Includes:
Fluke Ti95 Thermal Imager:- AC power adapter
- Lithium ion smart battery (1)
- USB cable
- SD memory card
- Fluke Connect™ wireless SD Card (where available, shipped separately in non-European countries)
- Soft transport bag
- Adjustable hand strap (left- or right-handed use)
- Printed users' manual in English, Spanish, French, German and Simplified Chinese, all other manuals on CD
- SmartView® software
- Warranty registration card
Fluke 3000 FC Wireless Digital Multimeter with three AA batteries - installed:
- TL175 Test Leads (1 pair)
- AC175 Alligator Clips (1 pair)
- C3003 3-compartment soft case
- Information pack
Fluke a3001 FC Wireless iFlex AC Current Module with two AA batteries - installed:
- iFlex 10"" coil (1)
- Magnet/strap (1)
Manuals + resources: Ti95 Fluke Connect FCA Kit
- Connecting a thermal imager to your iPhone
- Connecting multiple tools at the same time with Fluke Connect®
- Connecting the T3000 FC with the Fluke Connect™ app
- How to create an equipment baseline with EquipmentLog™ history
- How to email a measurement using the Fluke Connect app
- How to record measurements and graphs
- How to save measurements to EquipmentLog™ history
- How to share measurements on equipment using the Fluke Connect™ app
- Identifying intermittent conditions with TrendIt™ graphs
- Introduction to 789FC
- Measurement history in one place using EquipmentLog™ history
- Measuring from a safe distance using the Fluke Connect™ app
- Performing predictive maintenance with Fluke Connect™
- Saving measurements with AutoRecord™ measurements
- Share equipment health with EquipmentLog™ history
- Using ShareLive™ video call to share live measurements and video
- Viewing and graphing three phase measurements