Fluke i2500-10 iFlex® Flexible Current Probes | Fluke
English

Fluke i2500-10 iFlex® Flexible Current Probes

Fluke i2500-10 iFlex® Flexible Current Probes is rated 5.0 out of 5 by 1.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.4ms
  • REVIEWS, PRODUCT
  • Fluke i2500-10 iFlex® Flexible Current Probes
  • Fluke i2500-10 iFlex® Flexible Current Probes
  • Fluke i2500-10 iFlex® Flexible Current Probes
  • Fluke i2500-10 iFlex® Flexible Current Probes

Key features

  • Expands the measurement range to 2500 A AC while providing increased display flexibility, Ability to measure awkward sized conductors and improved wire access
  • CAT IV 600 V, CAT III 1000 V
  • 7.5 mm coil diameter allows measurement in tight spaces
  • Ergonomic design allows easy operation with one hand
  • 1.8 m (6 ft) Cable
  • Three-year warranty


How to Open the i2500-18 and i2500-10 iFlex® Flexible Current Probes:

Twist to Unlock

Pull to Open


Safety Conformance
IEC 61010-2-032 CAT III 1000 V / CAT IV 600 V

Product overview: Fluke i2500-10 iFlex® Flexible Current Probes

Be Ready for Anything

The Fluke iFlex® flexible current probes expand the measurement range of the select Fluke meters to 2500 A AC while providing the ultimate measurement flexibility. The iFlex® probes connect directly to the meter, displaying current measurements without error prone scaling factors. The 1.8 m (6 ft) cord allows separation between the measurement location and the clamp meter making it easier to view the display. The large loop size and thin cross section allow measurement of awkward sized conductors and improved wire access in crowded spaces. Available in 25 cm (10 in) and 45 cm (18 in) sizes.

Specifications: Fluke i2500-10 iFlex® Flexible Current Probes

Specifications
 RangeResolutionAccuracy
AC Current12500 A0.1 A3% ±5 digits2
Frequency1500 Hz0.1 Hz0.5% ±5 digits
External magnetic field rejection
(with cable > 10 cm from the coupling)
40 dB
Inrush1
Safety ratingCAT III 1000 V, CAT IV 600 V
1. When used with compatible Fluke meter. Accuracy stated includes probe and meter accuracy.
2. For position accuracy at non-optimum positions, see Position sensitivity specifications table “A”
Position sensitivity specifications
Distance from Optimumi2500-10Additional iFlex® Error
A0.5 in (12.7 mm)±0.5%
B0.8 in (20.3 mm)±1.0%
C1.4 in (35.6 mm)±2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature.

Models: Fluke i2500-10 iFlex® Flexible Current Probes

Fluke i2500 10
Buy it

Will this work with the 375c multimeter

Asked by: timmy12
Yes, the Fluke i2500-10 iFlex® Flexible Current Probes are compatible with the 375FC.
Answered by: FlukeCorporation
Date published: 2024-08-24

Does this work with the 902FC 

Asked by: Junior
The Fluke i2500-10 iFlex® Flexible Current Probes are not compatible with the Fluke 902 FC True-RMS HVAC Clamp Meter.
Answered by: FlukeCorp
Date published: 2023-04-19

Does this work with the 289

Asked by: B1234
  • y_2024, m_11, d_4, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_US, sid_3739301085236, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 23.1ms
  • QUESTIONS, PRODUCT
Rated 5 out of 5 by from Great Idea This is the best tool. Makes it so easy to use in tight places. If you get this tool you will love it.
Date published: 2012-10-25
  • y_2024, m_11, d_4, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_3739301085236, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.66ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat