Fluke 115 Digital Multimeter for Technicians
Key features
The 115 digital multimeter is for electrical and electronic testing in field service, industrial and applications where more than the basic functions are needed.
- Ideal for quick verifications and field service
- Min/Max/Average to record signal fluctuations
- CAT III 600V
Product overview: Fluke 115 Digital Multimeter for Technicians
Fluke 115 Digital Multimeter for Technicians
A compact trms digital multimeter for field service technicians
The Fluke 115 technicians digital multimeter is the compact, general purpose troubleshooting tool for field service technicians. Its simple, one-handed operation and compact design meets the needs of a wide variety of field service technicians. It measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency and capacitance for quick verifications.
The Fluke 110 Series has five true-rms digital multimeters, each for specific users. The compact instruments offer convenient one-handed operation and a backlit display with large, easy-to-read digits.
General purpose digital multimeter for electrical and electronic testing
- Ideal for quick verifications and field service
- Presents a large white LED backlight for working in poorly lit areas
- Measures AC and DC voltage to 600V
- Measures AC and DC current to 10A (20 A overload for 30-seconds max)
- Measures resistance, continuity, frequency, and capacitance
- Provides Min/Max/Average with elapsed time to record signal fluctuations
- Comes with a holster with probe holders for easy storage
- Features a compact ergonomic design for one-handed operation
- Fits into optional ToolPak™ magnetic hanger for hands-free operation
- CAT III 600 V safety rated
- For field service technicians, basic electronic repair.
Includes:
- Holster
- Installed 9V battery
- 4 mm silicone test lead set
- User manual - 2019 BEST PRODUCT IN CATEGORY
What's in the box:
- Digital multimeter
- Holster
- Installed 9V battery
- 4 mm PVC-Insulated test lead
- Quick Reference Guide
Specifications: Fluke 115 Digital Multimeter for Technicians
Specifications | |||
Maximum voltage between any terminal and earth ground | 600 V | ||
Surge protection | 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 | ||
Display | Digital: 6,000 counts, updates 4 per second | ||
Bar graph | 33 segments, updates 32 per second | ||
Operating temperature | -10°C to + 50°C | ||
Storage temperature | -40°C to + 60°C | ||
Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | ||
Battery life | 400 hours typical, without backlight | ||
Accuracy Specifications | |||
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV | |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | ||
DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V | |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | ||
AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV | |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | ||
AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V | |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | ||
Continuity | Range/resolution | 600 Ω / 1 Ω | |
Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. | ||
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ | |
Accuracy | 0.9% + 1 | ||
Range/resolution | 40.00 MΩ / 0.01 MΩ | ||
Accuracy | 5% + 2 | ||
Diode test | Range/resolution | 2.00 V / 0.001 V | |
Accuracy | 0.9% + 2 | ||
Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF | |
Accuracy | 1.9% + 2 | ||
Range/resolution | > 1000 μF | ||
Accuracy | 5% + 20% | ||
Lo-Z capacitance | Range | 1 nF to 500 μF | |
Accuracy | 10% + 2 typical | ||
AC amps True RMS (45 Hz to 500Hz) | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A | |
Accuracy | 1.5% + 3 20 A overload for 30-seconds max | ||
DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A | |
Accuracy | 1.0% + 3 20 A overload for 30-seconds max | ||
Hz (V or A input)2 | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.01 Hz 9.999 kHz / 0.001 kHz 50 kHz / 0.01 kHz | |
Accuracy | 0.1% + 2 | ||
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | |||
Mechanical & General Specifications | |||
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | ||
Weight | 550 g | ||
Warranty | 3 years |
Models: Fluke 115 Digital Multimeter for Technicians
Includes:
- Holster
- Installed 9V battery
- 4 mm PVC-Insulated test lead
- User manual