Fluke Ti27 Infrared Camera | Fluke
English

Fluke Ti27 Infrared Camera

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 21.46ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Fluke Ti27 Infrared Camera
  • Fluke Ti27 Infrared Camera
  • Fluke Ti27 Infrared Camera
  • Fluke Ti27 Infrared Camera
Discontinued

Key features

Superior image quality

  • Delivers the clear, crisp images needed to find problems fast with its 240 x 180 infrared resolution
  • Identify even the smallest temperature differences that could indicate problems with thermal sensitivity (NETD)
  • Automatic alignment (parallax correction) of visual and infrared images with Fluke patented IR-Fusion®
  • Optional telephoto and wide angle lenses available for added versatility and special applications. (easily installable in the field)

Easy to use

  • Field replaceable batteries give you maximum flexibility no matter where your work takes you
  • Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb
  • No need to carry pen and paper—record findings by speaking into the imager. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference
  • One-handed focus capability, emissivity correction, reflected background temperature compensation, and transmission correction increase the accuracy of measurements in most situations
  • Adjustable hand strap for left-or right-handed use
  • Everything needed to get started is included

Rugged

  • Optimized for field use in challenging work environments
  • Engineered and tested to withstand a 2 m drop for the ultimate peace of mind - When was the last time you dropped a tool or piece of equipment?
  • Withstands dust and water—tested to an IP54 rating
This product is discontinued or reclassified

Product overview: Fluke Ti27 Infrared Camera

Make no Mistake on Your Next Thermal Inspection with the Ti27

See the smallest visual and thermal details with the Ti27, a thermal imaging camera offering 240 x 180 resolution with IR-Fusion® Technology – the blending of digital and infrared images into a single image – delivering crisp quality images, making problem detection easy. With AutoBlend™, the Ti27 also produces partially transparent images that help identify issues and report findings easier.

The Optimal Choice in Advanced Infrared Troubleshooting

With thermal sensitivity of ≤ 0.05 °C at 30 °C (50 mK) and a temperature range from -20 ° to 600 °C (-4 ° to 1112 °F) the Ti27 is ideal for electrical and mechanical applications. Stop relying on pen and paper – let the voice annotation feature make documenting specific details easier than ever. For added versatility in your special applications, add our field-installable telephoto and wide angle lenses.

For applications that require a high temperature range and low thermal sensitivity (NETD), the Fluke Ti200 is an alternative choice. It features wireless connectivity for quick and easy sharing of images, LaserSharp® Auto Focus for consistently in-focus images – every, single, time and a ruggedized high resolution 640 x 480 capacitive touch screen for quick menu navigation.

As always, Fluke SmartView® Software is included at no additional charge.

Specifications: Fluke Ti27 Infrared Camera

Temperature
Temperature measurement range (not calibrated below -10°C)-20°C to +600°C (-4°F to +1112°F)
Temperature measurement accuracy± 2°C or 2% (at 25°C nominal, whichever is greater)
On-screen emissivity correctionYes
On-screen reflected background temperature compensationYes
On-screen transmission correctionYes
Imaging Performance
Image capture frequency9 Hz refresh rate or 60 Hz refresh rate depending upon model variation
Detector typeFocal Plane Array, uncooled microbolometer, 240 x 180 pixels
Total pixels43,200
Thermal sensitivity (NETD)≤ 0.05°C at 30°C target temp. (50 mK)
Infrared spectral band7.5 µm to 14 µm (long wave)
Visual (visible light) cameraIndustrial performance 2.0 megapixel
Minimum focus distance46 cm (approx. 18 in)
Standard infrared lens typeField of view23° x 17°
Spatial resolution (IFOV)1.67 mRad
Minimum focus distance15 cm (approx. 6 in)
Optional telephoto infrared lens typeField of view11.5° x 8.7°
Spatial resolution (IFOV)0.84 mRad
Minimum focus distance45 cm (approx. 18 in)
Optional wide-angle infrared lens typeField of view46° x 34
Spatial resolution (IFOV)3.34 mRad
Minimum focus distance7.5 cm (approx. 3 in)
Focus mechanismManual, one-handed Smart Focus capability
Image Presentation
PalettesStandardIronbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
Level and spanSmooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual and auto modesYes
Fast auto-rescale in manual modeYes
Minimum span (in manual mode)2.5°C (4.5°F)
Minimum span (in auto mode)5°C (9°F)
IR-Fusion® Information
Automatically aligned (parallax corrected) visual and IR blendingYes
Picture-In-Picture (PIP)Three levels of on-screen IR blending displayed in center of LCD
Full screen infraredThree levels of on-screen IR blending displayed in center of LCD
Color alarms (temperature alarms)High-temperature color alarm (user-selectable)
Image Capture and Data Storage
Image capture, review, save mechanismThe Ti27 allows user to adjust palette, blending, level, span, IR-Fusion® mode, emissivity, and reflected background temperature compensation, and transmission correction on a captured image before it is stored.
Voice annotation60 seconds maximum recording time per image; reviewable playback on imager
Storage mediumOne-handed image capture, review, and save capability
File formatsSD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader
Export file formats w/SmartView® softwareNon-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp and .jpeg) files
General Specifications
Operating temperature-10°C to +50°C (14°F to 122°F)
Storage temperature-20°C to +50°C (-4°F to 122°F) without batteries
Relative humidity10% to 95% non-condensing
Display9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover
Controls and adjustmentsUser selectable temperature scale (°C/°F)
Language selection
Time/Date set
Emissivity selection
Reflected background temperature compensation
Transmission correction
User selectable hot spot and cold spot, and center point on the image (other custom markers and shapes in SmartView® software)
High temperature color alarm
User selectable backlight: “Full Bright or "Auto"
Information display preference
SoftwareSmartView® full analysis and reporting software included
BatteriesTwo lithium ion rechargeable smart battery packs with five-segment LED display to show charge level
Battery lifeFour+ hours continuous use per battery pack (assumes 50% brightness of LCD)
Battery charge time2.5 hours to full charge
AC battery chargingTwo-bay AC battery charger (110 V AC to 220 V AC, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter.
AC operationAC operation with included power supply (110 V AC to 220 V AC, 50/60 Hz). AC mains adapters included.
Power savingSleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity
Safety standardsCSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
Electromagnetic compatibilityMeets all applicable requirements in EN61326-1:2006
C TickIEC/EN 61326-1
US FCCCFR 47, Part 15 Class B
Vibration0.03 g2/Hz (3.8 grms), IEC 68-2-6
Shock25 g, IEC 68-2-29
Drop2 m (6.5 ft) with standard lens
Dimensions (H x W x L)27.7 x 12.2 x 17.0 cm (10.9 x 4.8 x 6.7 in)
Weight (battery included)1.05 kg (2.3 lb)
Enclosure ratingIP54 (protected against dust, limited ingress; protection against water spray from all directions)
WarrantyTwo-years (standard)
Recommended calibration cycleTwo-years (assumes normal operation and normal aging)
Supported languagesCzech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish

Models: Fluke Ti27 Infrared Camera

Fluke Ti27
Fluke Ti27 Infrared Camera
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 23.16ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.84ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat