Fluke Ti450 PRO Infrared Camera | Fluke
English

Fluke Ti450 PRO Infrared Camera

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 21.63ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Fluke Ti450 PRO Infrared Camera
  • Fluke Ti450 PRO Infrared Camera - 2
  • Fluke Ti450 PRO Infrared Camera - 3
  • Fluke Ti450 PRO Infrared Camera - 4
Discontinued

Key features

  • Increased sensitivity to visualize temperature differences, NETD for the Ti450 PRO is ≤0.025 at 30 °C target temp (25 mK)
  • Easier to visualize and diagnose issues with sharper onscreen images, multiple rectangle markers and 9 color palettes
  • More intuitive visual interface, improved, user-tested, touch screen interface
  • More flexibility to visualize target, tiny-to-large with interchangeable smart lenses - no calibration required, 2x and 4x telephoto, wide angle and macro lens compatibility
  • Capture a clear, accurate image focused throughout the field of view with MultiSharp™ Focus
  • Get an instant in-focus image of your designated target. LaserSharp® Auto Focus uses a built-in laser distance meter that calculates and displays the distance from your designated target.
  • Get 4x the pixel data with SuperResolution, which captures multiple images and combines them to create a 640 x 480 image
  • Save time - wirelessly sync images directly from your camera to the Fluke Connect® system, and attach to an asset record or work order
  • Reduce the need take notes in the field with IR-PhotoNotes™ and voice annotations
This product is discontinued or reclassified

Product overview: Fluke Ti450 PRO Infrared Camera

Increased sensitivity to visualize differences

  • Capture smaller temperature differences with increased thermal sensitivity

Row of pipes, taken with manual focus
Old screen clarity versus the new sharper screen image

Easier to visualize and diagnose issues

  • Sharper onscreen images with better visual color differentiation
  • Display deviations from standard temperatures and communicate issues with your team using multiple Delta-T markers - choose one as a reference point and the others to display a value as a difference
  • Multiple rectangle markers in-camera - identify min/max temperatures for an area of the equipment or an equipment array
  • Distinguish heat differences more easily with a new palette and a wider array of yellows and greens in the display

New intuitive user interface

Old user interface

More intuitive visual interface

  • Improved, user-tested, touch screen interface leverages current styles and is more intuitive than ever

More flexibility to visualize targets -  tiny to large

  • Now compatible with all Fluke infrared smart lenses
  • Macro, telephoto and wide angle – from tiny to large, capture your target
  • Fluke smart lenses are interchangeable between compatible cameras without calibration

2 motors, taken with manual focus

With the Ti480 PRO MultiSharp™ focus captures images that are focused throughout the field of view, even if you start from a completely blurry target. The camera takes multiple images and combines them to give a clear, accurate focus on targets near and far. See more detail with SuperResolution, offering 4x the pixel data. Using the software and SuperResolution you can view images with up to 1280 x 960 resolution.


Save time with the Fluke Connect® system 
You can wirelessly sync images directly from your camera to the Fluke Connect® system, and attach it to an asset record or work order. Having access to maintenance records simultaneously at the inspection site and from the office or an off-site location enables faster decision making and real time collaboration between team members. You can also live stream the camera display to your smartphone or PC and remotely control the camera.
Technician reviewing measurements from Fluke Connect<sup>®</sup> tools on smartphone
Capture and save measurements from your wireless-enabled test
tools to the Fluke Connect® app on your smartphone.
Comparing two IR images on Fluke Connect™ Assets software
Asset analysis dashboard: Easily compare complex data.

Specifications: Fluke Ti450 PRO Infrared Camera

Key Features
IFOV with standard lens (spatial resolution)1.31 mRad, D:S 753:1
Detector resolution320 x 240
SuperResolutionCaptures and combines 4x the data to create a 640 x 480 (307,200 pixels) image
Infrared resolution76,800 pixels
MultiSharp™ Focus Yes, focused near and far, throughout the field of view
LaserSharp® Auto Focus Yes, for consistently in-focus images.
Laser distance meter Yes, calculates distance to the target for precisely focused images and displays distance on screen
Advanced manual focus Yes
Ruggedized touchscreen display 3.5 inch (landscape) 640 x 480 LCD
Rugged, ergonomic design for one-handed use Yes
Digital zoom 2x and 4x 
 
Temperature measurement
Temperature measurement range 
(not calibrated below -10 °C) 
-10 °C to +1500 °C (14 °F to 2732 °F)
Accuracy ±2 °C or 2% (at 25 °C nominal, whichever is greater)
Thermal sensitivity (NETD)*≤0.025 °C at 30 °C target temp (25 mK)
On-screen emissivity correction Yes (both value and table)
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes
*Best possible
 
Wireless connectivity
To PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available)
Fluke Connect® app compatible Yes, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect® app for saving and sharing
Fluke Connect® Assets optional softwareYes, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location.
Fluke Connect® Instant Upload Yes, connect your camera to your building's WiFi network, and images taken automatically upload to the Fluke Connect® system for viewing on your smartphone or PC
Fluke Connect® tool compatibleYes, connects wirelessly to select Fluke Connect® enabled tools and displays measurements on camera screen. Five simultaneous connections supported.
 
IR-Fusion® technology
Adds the context of the visible details to your infrared image
AutoBlend™ mode Min, Mid, Max IR plus full visible on camera; continously variable in software
Picture-In-Picture (PIP)Yes
Built-in digital camera (visible light)5 MP
 
Lenses
Standard lensIFOV (spatial resolution)1.31 mRad, D:S 753:1
Field of view24 °H x 17 °V
Minimum focus distance15 cm (approx. 6 in)
IR-Fusion® technologyPicture-In-Picture and full screen
Optional 2x telephoto smart lensIFOV (spatial resolution)0.65 mRad, D:S 1529:1
Field of view12 °H x 9 °V
Minimum focus distance45 cm (approx. 18 in)
IR-Fusion® technologyPicture-In-Picture and full screen
Optional 4x telephoto smart lensIFOV (spatial resolution)0.33 mRad, D:S 2941:1
Field of view6.0 °H x 4.5 °V
Minimum focus distance45 cm (approx. 18 in)
IR-Fusion® technologyPicture-In-Picture and full screen
Optional wide-angle smart lensIFOV (spatial resolution)2.62 mRad, D:S 377:1
Field of view 46 °H x 34 °VV
Minimum focus distance 15 cm (approx. 6 in)
IR-Fusion® technology Full screen
 
Level and spanSmooth auto and manual scaling
Fast auto toggle between manual and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.0 °C (3.6 °F)
Minimum span (in auto mode) 3.0 °C (5.4 °F)
 
Data storage and image capture
Extensive memory options Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload for permanent storage
Image capture, review, save mechanism One-handed image capture,review, and save capability
Image file formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files
Memory review Thumbnail and fullscreen review
Software SmartView® full analysis and reporting software with access to the Fluke Connect system
Export file formats with SmartView®software Bitmap (.bmp), GIF, JPEG, PNG, TIFF
Voice annotation 60 seconds maximum recording time per image; reviewable playback on camera, optional bluetooth headset available but not required
IR-PhotoNotes™Yes (5 images)
Text annotation Yes
Video recording Standard and radiometric
File formats video Non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3)
Streaming video (remote display) Yes, see the live stream of the camera display on your PC, smartphone, or TV monitor. Via USB, WiFi hotspot, or WiFi network to SmartView® software on a PC; via WiFi hotspot to the Fluke Connect® app on a smartphone; or via HDMI to a TV monitor
Remote control operation Yes, through SmartView® software or Fluke Connect® mobile app
Auto capture (temperature and interval) Yes
 
Battery
Batteries (field-replaceable, rechargeable) Two lithium ion smart battery packs with five-segment LED display to show charge level
Battery life 3-4 hours per battery (*Actual life varies depending on settings and usage)
Battery charge time 2.5 hours to full charge
Battery charging system Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter
AC operation AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
Power saving User selectable sleep and power off modes
 
Color palettes
Standard palettes 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™ palettes 9: Rainbow, Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
 
General specifications
Frame rate 60 Hz or 9 Hz versions
Laser pointer Yes
LED light (torch) Yes, improved output torch
Color alarms (temperature alarms) High temperature, low temperature, and isotherms (within range)
Center-point temperature measurementYes
Spot temperature Hot and cold spot markers
User-definable spot markers 3 user-definable spot markers
Center box Up to 3 expandable-contractible measurement box with MIN-MAX-AVG temp display
Infrared spectral band 7.5 μm to 14 μm (long wave)
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10% to 95% non-condensing
Safety IEC 61010-1: Overvoltage category II, Pollution Degree 2
Electromagnetic compatibility IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A
Australian RCM IEC 61326-1
US FCC CFR 47, Part 15 Subpart C Sections 15.207, 15.209, 15.249
Vibration 0.03 g2/Hz (3.8 g), 2.5 g IEC 68-2-6
Shock 25 g, IEC 68-2-29
Drop Engineered to withstand 2 meter (6.5 feet) drop with standard lens
Size (H x W x L)  27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in)
Weight (battery included)1.04 kg (2.3 lb)
Enclosure ratingIEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions)
WarrantyTwo-years (standard), extended warranties are available
Recommended calibration cycleTwo-years (assumes normal operation and normal aging)
Supported languagesCzech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish

how to calculate distance using fluke Ti450 PRO

Asked by: Ravi
  • y_2024, m_11, d_8, h_5CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestions, tq_1
  • loc_en_US, sid_ti450-pro, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 22.01ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.35ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.