What is a Clamp Meter? | Fluke
English

What is a clamp meter?

Clamp meters, Fundamentals
Basic features of a clamp meter

A clamp meter is an electrical testing tool that integrates a basic digital multimeter with a current sensor. Clamps measure current. Probes measure voltage. The integration of a hinged jaw into an electrical meter enables technicians to securely clamp around a wire, cable, or conductor at any point in an electrical system, facilitating current measurement in the circuit without the need for disconnection or de-energization.

Beneath their plastic moldings, the hard jaws consist of ferrite iron and are engineered to detect, concentrate, and measure the magnetic field generated by current as it flows through a conductor.

This versatile tool facilitates the accurate measurement of electric current without direct contact or circuit interruption, primarily through its clamping mechanism. It efficiently captures current readings while also providing the capability to measure voltage, resistance, and sometimes even frequency, making it an indispensable instrument in electrical maintenance and troubleshooting.

Best Clamp Meter Features

Originally designed for specific testing purposes, modern digital clamp meters now offer expanded measurement functions, increased accuracy, and, in some cases, specialized features. They encompass most basic functions of a digital multimeter (DMM), including voltage, continuity, and resistance measurements. Notable clamp meter features include:

  • Current-sensing jaw.
  • Tactile barrier (for finger protection from shocks).
  • Hold button: Freezes the display reading; released with a second button push.
  • Dial (also known as the rotary switch).
  • Display.
  • Backlight button.
  • Min Max button: Displays maximum input on the first push; subsequent pushes show minimum and average inputs in current, voltage, and frequency modes.
  • Inrush current button.
  • Zero button (yellow): Removes DC offset from DC current measurements and serves as the dial's shift button for selecting yellow functions.
  • Jaw release lever.
  • Alignment marks: Conductor alignment required to meet accuracy specifications.
  • Common input jack.
  • Volts/ohm input jack.
  • Input for flexible current probe.

How to use a clamp meter

Using a clamp meter effectively involves a combination of technical knowledge and practical skill. To start, ensure that the meter is set to the correct measurement type – current, voltage, resistance, or others as needed.

For current measurements, open the clamp by pressing the trigger and carefully encircle one of the wires in a circuit without touching it directly; this allows for non-contact current measurement. For voltage or resistance tests, use the probes, inserting them into the appropriate ports on the meter. Always observe safety protocols, including turning off power before connecting probes and never exceeding the meter's rated measurement range.

When measuring current, it's crucial to isolate the wire being tested to avoid inaccuracies from nearby wires. With the clamp securely around a single conductor, the meter will display the current flowing through it.

For voltage measurements, touch the probes to the corresponding test points - one to the live wire and the other to a neutral or ground line. The meter screen will display the voltage level.

Regular calibration and proper storage of the clamp meter are vital for maintaining its accuracy and longevity. Remember, understanding the specific features of your clamp meter model is key for its optimal use.

Why use a clamp meter?

Clamp meters have gained popularity for two main reasons:

  • Safety: clamp meters allow electricians to avoid the traditional method of cutting into a wire and inserting test leads for an in-line current measurement.
  • Convenience: There's no need to shut off the circuit carrying current during a measurement, significantly enhancing efficiency.

Clamp meters are preferred for measuring high levels of current. Digital multimeters cannot measure 10 A of current for more than 30 seconds without risking damage to the multimeter.

These meters typically offer a minimum current range of 0 A to 100 A, with many models extending up to 600 A, 999 A, or even 1400 A. Some plug-in clamp accessories, such as the iFlex®, can measure as high as 2500 A.

Digital clamp meter applications

Digital clamp meters find application in various settings, including industrial equipment, controls, residential/commercial/industrial electrical systems, and commercial/industrial HVAC. They are primarily utilized for service, installation, and maintenance purposes, offering a valuable tool for system troubleshooting and scheduled preventative maintenance.

Different types of clamp meters

Three main types of clamp meters exist:

  • Current transformer clamp meters: Measure only alternating current (AC).
  • Hall Effect clamp meters: Measure both alternating current and direct current (AC and DC).
  • Flexible clamp meters: Employ a Rogowski coil, measuring AC only, and are particularly useful for measuring in tight spaces. DC clamp meters, or hall effect clamp meters Hall Effect clamp meters can measure AC and DC currents. The core of these meters lies in their unique construction, featuring iron jaws that intensify the magnetic field around the conductor. They also use a Hall Effect sensor that converts this field into an electrical signal. Key to their accuracy is the process of zeroing, which compensates for external magnetic influences, ensuring precise current measurements.
Find the right clamp meter
Chat with ourFluke assistant
Clear Chat