Key features

  • Manufactured using a coil suspension element design for increased shock and vibration resistance, Mineral-insulated sheath with a minimum bend radius of 19 mm (3/4 in) for flexibility and durability

Specifications: Fluke 884X-RTD 100 Ohm RTD Temperature Probe

Specifications
ResistanceNominal 100 Ω
Temperature coefficient0.00385 Ω/Ω ºC nominal
Temperature range-200 C to 300 ºC (transition and cable temperature: 0 ºC to 25% ºC)
Drift rate+ 0.13 ºC at 0 ºC after 1000 hours at 300 ºC
Sheath Material316 stainless steel
LeadsPTFE-insulated, nickel-plated stranded copper, 22 AWG
Termination4-wire banana
Time constantFour seconds maximum for 63.2% response to step change in water moving at 3 fps
Bending radius19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip
CalibrationIncludes manufacturer’s NIST-traceable calibration and table with R vs. T values in 1 ºC increments from -196 ºC to 300 ºC. Callendar-van Dusen coefficients included
ImmersionAt least 100 mm (4 in) recommended
Accuracy (includes calibration uncertainty and short-term stability)±0.50 ºC at -196 ºC
±0.050 ºC at 0 ºC
±0.052 ºC at 200 ºC
±0.055 ºC at 300 ºC
Size9 in L x 3/16 in diameter
MarkingEach RTD is marked with the Fluke name and part number

Models: Fluke 884X-RTD 100 Ohm RTD Temperature Probe

884X-RTD
100 Ohm RTD Temperature Probe
Part#: 2675468

what is the alpha value of the probe?

Asked by: Dougcv63
Please call Fluke Calibration's Customer Care Center at +1 (877) 355-3225 or email us at info@flukecal.com.
Answered by: FlukeCorporation
Date published: 2023-12-14
  • y_2024, m_9, d_18, h_11CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_3839987974196, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 81.32ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.36ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat