Product overview: Fluke i430 Flex Current Clamp

The i430 Flex is an AC current probe utilizing the Rogowski principle. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas, without batteries or an external power source.

Also available as a pack of 4 pieces of the i430 current clamp, to be used for high current measurements. The Flex clamp fits around bus bars and large or hard-to-reach conductors. This 4-pack is perfect for use with 3-phase tools such as the Fluke 430 series.

Specifications: Fluke i430 Flex Current Clamp

General Specifications
Probe and cable materialTPE rubber, reinforced insulation
UL94 V-0, Colour: RED Munsell 7.5
R 1/14
Couplings materialPolypropylene, UL94 V-0
Probe cable length610 mm
Probe cable diameter12.4 mm
Probe cable bend radius40 mm
Output cable length2.5 meters RG58
Output connectorSafety BNC Connector
Operating range-20 to +90°C
Storage temperature-40 to +105°C
Operating humidity15% to 85% (non condensing)
Degree of protection (Probe)IP41
Specifications
Current range3000 A AC rms
Voltage output (@ 1000 A rms, 50 Hz)85 mV
Accuracy±1% of reading
(@ 25°C, 50 Hz)
Linearity (10% to 100% of range)±0.2% of reading
Noise (10 Hz – 7 kHz)1.0 mV AC rms
Output impedance82 Ω min
Load impedance50 kΩ
Internal Resistance per 100 mm probe length10.5Ω ±5%
Bandwidth (-3dB)10 Hz to 7 kHz
Phase error (45 – 65 Hz)±1°
Position sensitivity±2% of reading max.
Temperature coefficient±0.08% max of reading per °C
Working voltage (see Safety standards section)1000 V AC rms or DC (head)
30 V max. (output)
Safety Specifications
Safety standardsBS EN 61010-1 2001
BS EN 61010-2-032 2002
BS EN 61010-031 2002, 1000 VRMS, Category III, Pollution Degree 2
Use of the probe on uninsulated conductors is limited to 1000 V AC rms or DC and frequencies below 1 kHz.
Please note that this probe is designed to work with Fluke 435, if used with other products
Safety rating for the output to earth is limited to 600 V AC rms or DC.

Models: Fluke i430 Flex Current Clamp

Fluke I430-FLEX
Buy it

Is this CT compatible with the FLUKE 435-II analyzer

Asked by: BobR
  • y_2024, m_11, d_8, h_5CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestions, tq_1
  • loc_en_US, sid_fluke-i430-flex, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 59.8ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.2ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.