Fluke CNX v3000 AC Wireless Voltage Module
Fitur utama
The CNX v3000 AC Wireless Voltage Module provides:
- True RMS AC voltage measurements to 1000V
- ±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz
- Memory recording up to 65,000 readings
- Backlit LCD display
- CAT IV 600 V, CAT III 1000 V; IP42
The CNX wireless system can track up to 10 measurement modules simultaneously, with results sent to a PC for detailed analysis.
Ikhtisar Produk: Fluke CNX v3000 AC Wireless Voltage Module
The CNX v3000 Wireless Voltage Module is part of the Fluke team of wireless troubleshooting tools.
Connect the CNX v3000 AC Wireless Voltage Module to your test point, and view the results up to 20 meters away on the CNX 3000 Wireless Multimeter. You’ll save time, with less run-around collecting multiple measurements. Plus, no more writing down data as the CNX 3000 captures up to 65,000 sets of time stamped min/max/avg readings. CNX wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm’s way.
Spesifikasi: Fluke CNX v3000 AC Wireless Voltage Module
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
AC Voltage | |||
Range ¹ | Resolution | Accuracy ² ³ | |
45 Hz to 500 Hz | 500 Hz to 1 kHz | ||
6.000 V | 0.001 V | 1.0 % + 3 | 2.0 % + 3 |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V | ||
Notes: | |||
General Specifications | |||
LCD w/backlight | 3½ digits, 6000 counts, updates 4/sec | ||
Battery type | 2 AA, NEDA 15 A, IEC LR6 | ||
Battery life | 400 Hours | ||
Memory | Record up to 65,000 readings | ||
Unbound listen interval | 5 seconds | ||
RF communications | 2.4 GHZ ISM Band | ||
RF communication range | 20 Meters | ||
Operating temperature | -10 °C to +50 °C | ||
Storage temperature | -40 °C to +60 °C | ||
Operating humidity | 90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C | ||
EMC | EN 61326-1:2006 | ||
Safety compliance | EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III 600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010 EN/IEC 61010-031:2002+A1:2008 | ||
Pollution degree | 2 | ||
Temperature coefficient | 0.1 X (specified accuracy)/ °C (< 18 °C or > 28 °C) | ||
Safety rating | CAT IV 600 V, CAT III 1000 V | ||
Certifications | CSA, FCC T68-FWCS IC:6627A-FWCS | ||
Ingress protection (IP) rating | IP42 | ||
Size (HxWxD) | 16.5 x 6.35 x 3.56 cm (6.5 x 2.5 x 1.4 in) | ||
Weight | .22 kg (8 oz) |
Manual + Sumber: Fluke CNX v3000 AC Wireless Voltage Module
- CNX 3000 | Manual Pengguna
- CNX 3000 | Tambahan Manual Pengguna
- CNX 3000 | Manual Kalibrasi
- CNX 3000 | Pernyataan ketidakstabilan memori
- CNX 3000 | Lembar Petunjuk
- CNX a3000 | Panduan Referensi Cepat
- CNX a3000 | Lembar Keamanan
- CNX i3000 | Manual Kalibrasi
- CNX i3000 | Tambahan Manual Kalibrasi
- CNX i3000 | Lembar Keamanan
- CNX t3000 | Manual Kalibrasi
- CNX t3000 | Panduan Referensi Cepat
- CNX t3000 | Lembar Keamanan
- CNX v3000 | Panduan Referensi Cepat
- CNX v3000 | Manual Kalibrasi
- CNX v3000 | Lembar Keamanan
- CNX v3000, CNX t3000, CNX i3000, CNX a3000 | Pernyataan ketidakstabilan memori