Fluke CNX 3000 Wireless Multimeter
Fitur utama
The CNX 3000 Wireless Multimeter has all the essentials for convenient test and measurement troubleshooting.
- AC and DC voltage measurements to 1000V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX Recording
- CAT III 1000 V, Cat IV 600 V; IP54
Plus, the CNX wireless enabled modules measure AC voltage, AC current and temperature, which display on the CNX Wireless Multimeter. Choose a standard clamp or flexible clamp to measure AC current. Mix and match modules to suit your unique measurement needs. Read the primary measurement on the main display, and up to three modules at any one time. Modules are available separately or as part of CNX kits.
Ikhtisar Produk: Fluke CNX 3000 Wireless Multimeter
The CNX 3000 Wireless Multimeter is the captain of the Fluke wireless team.
With the CNX 3000 Wireless Multimeter, you see live measurements from multiple modules simultaneously and remotely on a single screen. The CNX 3000 Wireless Multimeter displays the meter measurement, plus readings from up to 3 wireless modules, as far as 20 meters away. By seeing multiple readings at the same time, troubleshooters can see cause and effect, interactions between inputs/outputs or other measurement points, simultaneously and remotely.
If more than three readings are required from more modules, add an optional PC adapter to your laptop for real time viewing of up to 10 modules.
Spesifikasi: Fluke CNX 3000 Wireless Multimeter
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications | ||||||
AC Voltage | ||||||
Range ¹ / Resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | |||||
Accuracy ², ³ | 45 Hz to 500 Hz | 1.0 % + 3 | ||||
500 Hz to 1 kHz | 2.0 % + 3 | |||||
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range. |
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | ||
Function | ||
mV | Range ¹ / Resolution | 600.0 mV / 0.1 mV |
Accuracy | 0.09 % + 2 | |
V | Range ¹ / Resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
Accuracy | 0.09 % + 2 0.15 % + 2 | |
))) | Range ¹ / Resolution | 600 Ω / 1 Ω |
Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | |
Ω | Range ¹ / Resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ |
Accuracy | 0.5 % + 2 0.5 % + 1 1.5 % + 3 | |
Diode test | Range ¹ / Resolution | 2.000 V0.001 V |
Accuracy | 1 % + 2 | |
μF | Range ¹ / Resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF ¹ / 1 μF |
Accuracy | 1.2 % + 2 10 % | |
¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2. | ||
AC and DC Current | ||
Function | ||
mA AC (45 Hz to 1 kHz) | Range ¹ / Resolution | 60.00 mA / 0.01 mA 400.0 mA ³ / 0.1 mA |
Accuracy | 1.5 % + 3 | |
mA DC ² | Range ¹ / Resolution | 60.00 mA / 0.01 mA 400.0 mA / 0.1 mA |
Accuracy | 0.5 % + 3 | |
¹ All AC current ranges are specified from 5 % of range to 100 % of range. | ||
Frequency | ||
Range ¹ / Resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz | |
Accuracy | 0.1 % + 1 | |
¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | ||
Input Characteristics | ||
Function | ||
OverloadProtection | 1100 V RMS | |
Input Impedance (nominal) | > 10 MΩ < 100 pF | |
Common Mode Rejection Ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | |
Normal Mode Rejection | > 60 dB at 50 Hz or 60 Hz | |
OverloadProtection | 1100 V RMS | |
Input Impedance (nominal) | > 10 MΩ < 100 pF | |
Common Mode Rejection Ratio (1 kΩ unbalance) | > 60 dB, DC to 60 Hz | |
OverloadProtection | 1100 V RMS | |
Input Impedance (nominal) | > 10 MΩ < 100 pF | |
Common Mode Rejection Ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | |
Normal Mode Rejection | > 60 dB at 50 Hz or 60 Hz | |
Open circuit test voltage | ||
OverloadProtection | 1100 V RMS | |
Input Impedance (nominal) | < 2.7 V DC | |
Full scale | To 6 MΩ: < 0.7 V DC 50 MΩ: < 0.9 V DC | |
Typical short circuit current | < 350 mA | |
OverloadProtection | 1100 V RMS | |
Input Impedance (nominal) | < 2.7 V DC | |
Full scale | To 6 MΩ: 2.000 V DC | |
Typical short circuit current | < 1.1 mA | |
mA | Overload Protection | Fused, 44/100 A, 1000 V FAST Fuse |
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | |
MIN/MAX Recording | ||
DC functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration | |
AC functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration |
General Specifications | |
Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS |
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |
Display (LCD) | Update rate: 4/sec Volts, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts |
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 |
Battery life | 300 hours minimum |
Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C |
Relative humidity | 0 % to 90 % (0 °C to 35 °C) 0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C) |
Altitude | Operating: 2,000 m Storage: 12,000 m |
Temperature coefficient | 0.1 X (specified accuracy) / °C (< 18 °C or > 28 °C) |
Wireless frequency | 2.4 GHz ISM Band 20 meter range |
Size (H x W x L) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) |
Weight | 340 g (12 oz) |
Safety standards | US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition CE European: IEC/EN 61010-1:2010 |
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : T68-FWCS IC:6627A-FWCS |
Ingress Protection (IP) rating | IP54 |
Model: Fluke CNX 3000 Wireless Multimeter
Includes:
- True RMS Wireless Multimeter
- TL175 Test Leads
- AC175 Alligator Clips
Manual + Sumber: Fluke CNX 3000 Wireless Multimeter
- CNX 3000 | Manual Pengguna
- CNX 3000 | Tambahan Manual Pengguna
- CNX 3000 | Manual Kalibrasi
- CNX 3000 | Panduan Referensi Cepat
- CNX 3000 | Pernyataan ketidakstabilan memori
- CNX 3000 | Lembar Petunjuk
- CNX 3000 | Lembar Keamanan
- CNX 3000 | Tambahan Lembar Keamanan
- CNX a3000 | Panduan Referensi Cepat
- CNX a3000 | Manual Kalibrasi
- CNX a3000 | Lembar Keamanan
- CNX i3000 | Lembar Keamanan
- CNX i3000 | Manual Kalibrasi
- CNX i3000 | Tambahan Manual Kalibrasi
- CNX i3000 | Panduan Referensi Cepat
- CNX t3000 | Manual Kalibrasi
- CNX t3000 | Panduan Referensi Cepat
- CNX t3000 | Lembar Keamanan
- CNX v3000 | Panduan Referensi Cepat
- CNX v3000 | Manual Kalibrasi
- CNX v3000 | Lembar Keamanan
- CNX v3000, CNX t3000, CNX i3000, CNX a3000 | Pernyataan ketidakstabilan memori
- Radio Frequency Data Class A | Lembar Petunjuk
- Radio Frequency Data Class B | Lembar Petunjuk
- v3000 FC, v3001 FC, a3000 FC, a3001 FC, a3002 FC, t3000 FC | Pernyataan ketidakstabilan memori