Fitur utama

  • Unlimited applications – See data sheet for powerful applications and details
  • Built-in digital camera – Every Fluke Visual IR Thermometer has a built-in digital camera
  • Exclusive thermal heat map blending overlay – With one button, blend digital images and thermal heat maps to instantly show the exact location of the issue
  • No training required - Fully automatic with built-in intelligence
  • True pocket size design – Less than half the size of an average infrared camera
  • SmartView® reporting software – Store up to 10,000 images per Gb on included SD card and make professional reports on included professional software
  • Automatic hot and cold spot trackers
  • Breakthrough affordability – Fraction of the cost of infrared cameras that require costly training and software
  • Powerful resolution with PyroBlend® Plus optics:
    • Best-in-class field of view: 28 ° x 28 ° (40% wider for tight spaces)
    • 4 times sharper images
  • Alarm and time lapse features:
    • Hi/Lo temperature alarm – Find hot spots in seconds with the alarm feature
    • Time lapse image capture – Automatically monitor equipment over time
    • Automated monitoring alarm – Automatically capture images after an alarm has been triggered
Produk ini dihentikan atau diklasifikasikan ulang

Ikhtisar Produk: VT04 Visual IR Thermometer Maintenance Combo Kit

VT04 dan Fluke 1507 Insulation Resistance Tester merupakan teman ideal untuk aplikasi pemecahan masalah dan pemeliharaan preventif.

Spesifikasi: VT04 Visual IR Thermometer Maintenance Combo Kit

Fluke VT04 Visual IR Thermometer

 
Fitur Utama
Kamera digital bawaanYa
Lapisan peta panas termalYa, lima mode kombinasi
Sistem optik citraOptik PyroBlend® Plus gambar 4x lebih tajam daripada VT02
Medan pandang28° x 28°
Alarm suhu HI-LoYa
Tangkapan gambar selang waktuYa
Alarm monitor otomatisYa
Jenis BateraiLi-Ion dapat diisi ulang
PelatihanTidak perlu pelatihan
ErgonomikDesain ramping seukuran saku
Penanda panas dan dinginYa
Fitur Umum
Daya tahan bateraiDelapan (8) jam
Rentang pengukuran suhu-10°C s/d +250°C (14°F s/d 482°F)
Akurasi pengukuran suhu±2°C atau ±2%
Pengukuran suhuYa, titik tengah
Media penyimpanan (kartu mikro SD)Menyimpan hingga 10.000 gmabar per GB (Kartu empat (4) GB disertakan)
Pita spektrum inframerah6,5 µm sampai 14 µm
Tinggi dan bentangOtomatis
Mekanisme fokusBebas fokus, tidak dibutuhkan pelatihan dan dengan kecerdasan bawaan
Opsi fokus-opsi NEAR/FAR yang secara eksklusif dapat dipilih oleh penggunaNEAR > 23 cm (9 in); FAR < 23 cm (9 in)
Dimensi21 x 7,5 x 5,5 cm (8,3 x 3 x 2,2 in); < 350 g. (12,5 oz.)
FileformatFormat .is2 disimpan ke kartu SD Pengguna dapat membuat laporan secara profesional atau mengekspor gambar dalam SmartView (BMP, DIB, GIF, SPE, FIF, SPEG, JPG, PNG, TIF dan TIFF)
Keamanan dan kesesuaianCFR47:2009 Kelas A. Komponen 15 subkomponen B; CE EN 61326:2006; IEC/EN 61010-1:2010
GaransiDua (2) tahun

Fluke 1507/1503 Insulation Resistance Testers

 
Pengukuran Tegangan AC/DC
AkurasiRentang600,0 V
Resolusi0,1 V
50 Hz s/d 400 Hz ± (% of Rdg + Digit)23
Impedansi input3 MΩ (nominal) 100 pF
Rasio penolakan mode umum selisih 1 kΩ60 dB pada dc 50 atau 60 Hz
Perlindungan Beban BerlebihRms atau dc 600 V

 

Pengukuran Tahanan Ikatan Bumi
Rentang/Resolusi20,00 Ω0,01 Ω
200,0 Ω0,1 Ω
2000 Ω1,0 Ω
20,00 kΩ0,01 kΩ
Akurasi±(1,5% + 3)
Perlindungan Beban BerlebihRms atau dc 2 V
Tegangan Uji Sirkuit Terbuka> 4,0 V, < 8 V
Arus hubung singkat> 200,0 mA

 

Spesifikasi Insulasi
Rentang pengukuran15070,01 MΩ s/d 10 GΩ
15030,01 MΩ s/d 2.000 MΩ
Teganganuji150750 V, 100 V, 250 V, 500 V, 1000 V
1503500 V, 1000 V
Akurasi tegangan uji+20%, - 0%
Arus hubung singkatnominal 1 mA
Otomatis pelepasan daya otomatisWaktupelepasan < 0,5 detikuntuk C = 1 µF ataukurang
Indikator sirkuit langsungMembatalkan pengujian jika tegangan terminal > 30 V sebelum penyiapan pengujian
Muatan kapasitif maksimumDapat dioperasikan dengan muatan hingga 1 µF
Akurasi pengukuran50 V±(3% + 5)
100 V±(3% + 5)
250 V±(1,5% + 5)
500 V±(1,5% + 5)
1000 V±(1,5% + 5) s/d 2.000 MΩ ±(10% + 3) diatas 2.000 MΩ

 

Spesifikasi Umum
Tegangan maksimum yang diterapkan di setiap terminalRms atau dc ac 600 V
Suhu penyimpanan-40°C sampai 60°C (-40°F sampai 140°F)
Suhu pengoperasian-20°C sampai 55°C (-4°F sampai 131°F
Koefisien suhu0,05 x (akurasi tertentu) per °C untuk suhu < 18°C atau > 28°C (< 64°F atau > 82°F)
Kelembapan relatif0% s/d 95% @ 10°C s/d 30°C (50°F s/d 86°F)
0% s/d 75% @ 30°C s/d 40°C (86°F s/d 104°F)
0% s/d 40% @ 40°C s/d 55°C (104°F s/d 131°F)
GetaranAcak 2 g 5 - 500 Hz per MIL-PRF-28800F Instrumen kelas 2
GuncanganJatuh 1 meter per Edisike 2 IEC 61010-1 (tes jatuh 1 meter enam sisi lantai kayu oak)
Kompatibilitas elektromagnetikPada medan RF 3 V/M akurasi = akurasi tertentu (EN 61326-1:1997)
KeselamatanMematuhi ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, dan Edisi ke-2 IEC/EN 61010-1 untuk kategori pengukuran IV 600 V (CAT IV)
SertifikasiCSA per standar CSA/CAN C22.2 No. 61010.1-04; TUV per standar Edisi ke-2 IEC/EN 61010-1
BateraiEmpat baterai AA (NEDA 15A atau IEC LR6)
Daya tahan bateraiPenggunaan uji insulasiPenguji dapat melakukan sedikitnya 1.000 uji Insulation dengan baterai alkaline yang baru pada suhu ruangan. Berikut adalah uji standar 1.000 V ke 1 MΩ dengan siklus kerja 5 detik hidup dan 25 detik mati.
Hambatan pengukuranPenguji dapat melakukan sedikitnya 2.500 pengukuran tahanan dengan baterai alkaline yang baru pada suhu ruangan. Berikut adalah uji standar 1 Ω dengan siklus kerja 5 detik hidup dan 25 detik mati.
Ukuran5,0 cm H x 10,0 cm W x 20,3 cm L (1,97 untuk H x 3,94 untuk W x 8,00 untu k L)
Berat550 g (1,2 lb)
RatingIPIP40
KetinggianPengoperasian2.000 m CAT IV 600 V 3.000 m CAT III 600 V
Non-operasi (penyimpanan)12.000 m
Kapabilitas kelebihan rentang110% dari rentang
Aksesori yang disertakanKabel Uji TL224, Probe Uji TP74, jepit PN 1958654 (merah) dan PN 1958646 (hitam) sarung dan remote probe

Model: VT04 Visual IR Thermometer Maintenance Combo Kit

Fluke VT04-Maint-Kit
Fluke VT04 Visual IR Thermometer Maintenance Combo Kit

Includes:

VT04 Visual IR Thermometer includes:

  • Hard case*
  • Micro-SD card
  • Micro-SD conversion adapter to standard
  • Li-Ion rechargeable battery
  • Printed Quick Start guides (English, French, German, Spanish, Simplified Chinese)

Available for free download*:

*To lower pricing on the VT04, future inventory no longer includes the lanyard, the SmartView® software CD, and the Manual CD.

1507 Insulation Tester includes: