Fluke 117 Multimeter and PRV240 Proving Unit Kit | Fluke
Português

Fluke 117 Multimeter and PRV240 Proving Unit Kit

  • Fluke 117 DMM / PRV240 Proving Unit Kit
  • Fluke 117 DMM / PRV240 Proving Unit Kit
  • Fluke 117 DMM / PRV240 Proving Unit Kit
  • Fluke 117 DMM / PRV240 Proving Unit Kit
  • The PRV240 provides safe verification your test tool is operating properly

Principais recursos

  • True-rms electrician’s digital multimeter with non-contact voltage detection, AutoVolt automatic ac/dc voltage selection
  • Reduces the risk of shock and arc flash by validating the functionality of test tools without placing yourself in a potentially hazardous electrical environment

Informações gerais sobre o produto: Fluke 117 Multimeter and PRV240 Proving Unit Kit

The Fluke 117 multimeter and PRV240 Proving Unit Kit combines a general-purpose electrician’s digital multimeter with a portable, pocket-sized, battery-powered voltage source that provides a safe method to verify that your electrical test tool is operating properly before you conduct any live tests.

Fluke 117 Electrician’s Multimeter

The Fluke 117 Electricians Multimeter includes integrated non-contact voltage detection, AutoVolt and LoZ functions for faster, more accurate readings. It is a compact true-rms meter for demanding applications like commercial buildings, hospitals, and schools.

Fluke 117 key functions

Integrated VoltAlert™ technology for fast, go/no go non-contact voltage detection. Features AutoVolt automatic ac/dc voltage selection

  • Provides low input impedance to help prevent false readings due to ghost voltage
  • Provides Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated

PRV240 Proving Unit

The Fluke PRV240 Proving Unit is a portable, pocket-sized, battery-powered voltage source. It is unique in that it sources stable ac and dc voltages for both LoZ and HiZ instruments.

PRV240 Proving Unit key functions

A single LED indicates functionality, making this unit a simple-to-use solution for complying with TBT verification of your test tool. Voltage is sourced through recessed contacts that are activated when test probes are inserted, preventing accidental contact.

  • Includes TPak™ Magnetic Hanging Strap
  • Long battery life—5,000 tests per set of four AA batteries

Especificações: Fluke 117 Multimeter and PRV240 Proving Unit Kit

Specifications
Maximum voltage between any terminal and earth ground600 V
SafetyIEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Fuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Battery type9 volt Alkaline, IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/resolution600.0 mV / 0.1 mV
Accuracy±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/resolution600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMSRange/resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMSRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
OhmsRange/resolutionOhms Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/resolution40.00 MΩ / 0.01 MΩ
Accuracy5% + 2
Diode testRange/resolution 
Accuracy0.9% + 2
CapacitanceRange/resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy1.9% + 2
Range/resolution> 1000 μF
Accuracy5% + 20%
Lo-Z capacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz)Range/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.5% + 3
20 A continuous overload for 30 seconds max
DC ampsRange/resolution6.000 A / 0.001 A 10.00 A / 0.01 A
Accuracy1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)²Range/resolution99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

Fluke PRV240 Proving Unit

General Specifications
Output voltage240 V ac rms or dc± 10 % ≥ 1 MΩ
 LoZ >3 kΩ load60 V ac typical
50 V ac rms minimum
LED power indicatorTurns on when output voltage is present
Battery4 AA Alkaline batteries NEDA24 A IEC LR03
Battery life5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ load
Operating temperature-10 °C to +50 °C
Operating humidity0 % to 90 % (0 °C to 35 °C)
0 % to 70 % (35 °C to 55 °C)
Operating altitude2000 m
Dimensions11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2
Weight0.23 kg (8 oz) includes batteries
SafetyIEC61010-1, IEC61010-2-030
WarrantyOne-year
Electromagnetic Compatibility (EMC)IEC 61326-1Portable EM environment; CISPR 11, Group 1, Class A
US (FCC)47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

Modelos: Fluke 117 Multimeter and PRV240 Proving Unit Kit

FLUKE-117-PRV240

Fluke 117 DMM / Kit da Unidade de testes PRV240

Comprar

Inclui:

Multímetro do eletricista com detecção de tensão sem contato

  • Conjunto de pontas de prova de silicone de 4 mm
  • Bateria alcalina de 9 volts (instalada)
  • Capa protetora (holster)
  • Manual do usuário

Unidade de testes Fluke PRV240

  • Faixa para pendurar TPAK
  • Quatro pilhas AA
  • Folha de instruções
Converse com oAssistente da Fluke
Limpar conversa
[object Object]