Fluke i430 Flex Current Clamp | Fluke
ภาษาไทย

ภาพรวมผลิตภัณฑ์: Fluke i430 Flex Current Clamp

The i430 Flex is an AC current probe utilizing the Rogowski principle. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas, without batteries or an external power source.

Also available as a pack of 4 pieces of the i430 current clamp, to be used for high current measurements. The Flex clamp fits around bus bars and large or hard-to-reach conductors. This 4-pack is perfect for use with 3-phase tools such as the Fluke 430 series.

ข้อมูลจำเพาะ: Fluke i430 Flex Current Clamp

General Specifications
Probe and Cable Material
 TPE rubber, reinforced insulation
 UL94 V-0, Colour: RED Munsell 7.5
 R 1/14
Couplings Material
 Polypropylene, UL94 V-0
Probe Cable Length
 610 mm
Probe Cable Diameter
 12.4 mm
Probe Cable Bend Radius
 40 mm
Output cable length
 2.5 meters RG58
Output Connector
 Safety BNC Connector
Operating Range
 -20 to +90°C
Storage Temperature
 -40 to +105°C
Operating Humidity
 15% to 85% (non condensing)
Degree of protection (Probe)
 IP41
Specifications
Current Range
 3000 A AC RMS
Voltage output (@1000 ARMS, 50 Hz)
 85 mV
Accuracy
 ± 1% of reading
 (@ 25°C, 50 Hz)
Linearity (10% to 100% of range)
 ± 0.2% of reading
Noise (10 Hz – 7 kHz)
 1.0 mV ACRMS
Output impedance
 82 Ω min
Load Impedance
 50 kΩ
Internal Resistance per 100 mm probe length
 10.5Ω ± 5%
Bandwidth (-3dB)
 10 Hz to 7 kHz
Phase Error (45 – 65 Hz)
 ±1°
Position Sensitivity
 ± 2% of reading max.
Temperature Coefficient
 ± 0.08% max of reading per °C
Working Voltage (see Safety Standards section)
 1000 V AC RMS or DC (head)
 30 V max. (output)
Safety Specifications
Safety Standards
 BS EN 61010-1 2001
 BS EN 61010-2-032 2002
 BS EN 61010-031 2002, 1000 VRMS, Category III, Pollution Degree 2
 Use of the probe on uninsulated conductors is limited to 1000 V ACRMS or DC and frequencies below 1 kHz.
 Please note that this probe is designed to work with Fluke 435, if used with other products
 safety rating for the output to earth is limited to 600V ACRMS or DC.