Key features

87V MAX: This electrical multimeter contains all the trusted features of the most popular multimeter used today, the Fluke 87V, plus much more.

  • More rugged: The 87V MAX multimeter withstands drops up to 4-meters (13 feet) with industrial strength casing and holster
  • Use it everywhere: Waterproof, dustproof IP67 case for the most extreme work sites
  • Easy to use: Large display digits, backlit keys for dark environments and double the battery life of the 87V (up to 800 hours)
  • Save time: Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
  • Premium TL175 TwistGuard™ test leads

Product overview: Fluke 87V MAX True-rms Digital Multimeter

Fluke 87V MAX TRMS Digital Multimeter

The Fluke 87V MAX trms multimeter defines a new standard for operating in extreme conditions, with the features and accuracy to troubleshoot most electrical problems

Withstands drops up to 4-meters (13 feet)

Fluke’s most rugged digital multimeter. The 87V MAX is a trms multimeter built with an industrial strength case and a removable holster. The holster doubles as a test probe holder for one-handed operation.

IP67 rated

This Fluke digital multimeter is fully waterproof and dust proof, to work reliably in all the places that you need to work.

Withstands heat and cold

The Fluke 87V MAX TRMS multimeter has an extended operating temperature range of -40 °C (for up to 20 minutes) to +55 °C.

Other product highlights

  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Measure up to 1000 V ac and dc
  • Measure up to 10 A (20 A for 30 seconds)
  • Frequency to 200 kHz
  • Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
  • Min/Max/Average recording, plus 250 μs Peak min-max to capture variations automatically
  • Unique function for accurate voltage and frequency measurements on variable frequency motor drives (VFDs) and other electrically noisy equipment
  • This electrical multimeter has a large display digits, 2-level bright white backlight and backlit keypad buttons for increased visibility
  • Hi resolution 19,999 count display mode
  • Long battery life (800 hours)

Comparison – 87V MAX multimeter and 87V multimeter

87V MAX ; 87 V

IP Rating: IP 67 ; IP 30

Battery life: 800 hours; 400 hours

Drop test: 4 meters ; 3 meters

Backlit keypad: Yes ; No

TwistGuard™ test leads: Yes ; No

True-rms readings: ac ; ac

Basic dc accuracy: 0.05% ; 0.05%

Voltage ac/dc: 1000 V ;1000 V

Current ac/dc :10 A ; 10 A

Resistance: 50 MΩ ; 50 MΩ

EN61010-1 CAT III: 1000 V ; 1000 V

EN61010-1 CAT IV: 600 V ; 600 V

Warranty (years) Limited lifetime : Limited ; lifetime

What's in the box:

  • Fluke 87V MAX True-rms Digital Multimeter
  • TL175 TwistGuard® test leads
  • AC175 Alligator clips
  • 80BK-A temperature probe
  • Removable holster with test lead storage
  • Three AA batteries (installed) 

Specifications: Fluke 87V MAX True-rms Digital Multimeter

Electrical Specifications
DC VoltageRange0.1 mV to 1000 V
Accuracy±(0.05% + 1)
Maximum resolution0.1 mV
AC VoltageRange0.1 mV to 1000 V
Accuracy±(0.7% + 4) true-rms
AC bandwidth20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution0.1 mV
DC CurrentRange0.1 μA to 10 A
(20 A for 30 seconds maximum)
Amps accuracy±(0.2% + 2)
Maximum resolution0.1 µA
AC CurrentRange0.1 μA to 10 A
(20 A for 30 seconds maximum)
Amps accuracy±(1.0% + 2) true-rms
Maximum resolution0.1 µA
ResistanceRange0.1 Ω to 50 MΩ
Accuracy±(0.2% + 1)
Maximum resolution0.1 Ω
CapacitanceRange0.01 nF to 9999 μF
Accuracy±(1% + 2)
Maximum resolution0.01 nF
FrequencyRange0.5 Hz to 199.99 kHz
Accuracy±(0.005% + 1)
Maximum resolution0.01 Hz
Duty cycleMaximum duty cycle99.9%
Accuracy±(0.2% per kHz + 0.1%)
Maximum resolution0.1%
Temperature measurement range–200.0 °C to 1090 °C
–328.0 °F to 1994.0 °F
excluding probe
80 BK temperature probe–40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater
–40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater
ConductanceMaximum conductance60.00 nS
Accuracy±(1.0% + 10)
Maximum resolution0.01 nS
Diode testRange2 V
Resolution0.001V
Accuracy±(1% + 1)
Diagnostics and data storagePeak Min/Max250 μS
Min/Max/AvgYes
Reading hold/Auto (Touch) HoldYes
Relative referenceYes
DisplayDigital6000 counts updates 4/second
19,999 counts in high–resolution mode
Analog bar graph32 segments, updates 40/second
BacklightTwo level
Low pass filter (VFD measurements)Yes
Input Alert™Yes
Safety Specifications
Safety ratingIEC61010-1: Pollution Degree 2
IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V
Agency approvalsCE, CSA
Mechanical and General Specifications
IP ratingIEC 60529: IP67
PowerThree AA batteries. 800 hours typical, without backlight
Size6.0 x 10.1 x 21.5 cm (with holster)
Weight698.5 g (with holster)
WarrantyLimited lifetime
Environmental Specifications
Operating temperature-15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C
Storage temperature-40 °C to + 60 °C
Humidity (without condensation)0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)
Operating altitude2000 m

Models: Fluke 87V MAX True-rms Digital Multimeter

Fluke 87V MAX

Fluke 87V MAX True-rms Digital Multimeter

Buy it

Includes:

  • TL175 TwistGuard® test leads
  • AC175 Alligator clips
  • 80BK-A temperature probe
  • Removable holster with test lead storage
  • Three AA batteries (installed)

How do I calibrate this meter? I have an older procedure downloaded for a 5502A but it fails to run. There are no procedures that I can find on the Cubyt server. It is like Fluke doesn't know what to do with it.

Asked by: devedo
  • y_2024, m_11, d_4, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestions, tq_1
  • loc_en_US, sid_4330750410804, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 47.18ms
  • QUESTIONS, PRODUCT
Rated 5 out of 5 by from Review on Fluke 87 V MAX Excellent DMM for technician/engineers working in extreme environment. One of the Most accurate among DMM
Date published: 2023-06-30
Rated 4 out of 5 by from great meter Sure would have been nice to get a printed manual with it. no response from customer service
Date published: 2023-03-28
Rated 5 out of 5 by from Fluke 87V max I'm new to multimeters, but the Fluke 87 has a phenomenal reputation and the max version gives me piece of mind when the meter is sitting on an engine bay outside with the potential for falling or getting rained on. It was expensive, but I paid the premium because these are still made in the USA.
Date published: 2022-03-21
Rated 5 out of 5 by from First Fluke, Great Choice Great meter. Easy to use, reads well. Glad to finally break into the Fluke family with this amazing meter
Date published: 2022-03-01
Rated 5 out of 5 by from Best 20,000 Count Handheld DMM Available I've owned my 87-V Max for about a year. I like that it accurately measures current draw with DC induction motors using inverters and PWM controllers; measurements that fool other meters. I have no idea how this works, but I performed the calculations, and the meter read ~the correct value. It is perfectly accurate at 10VDC, measured against a Fluke 732B DC Standard. The 732B is a bit overkill for a handheld DMM, but it doesn't harm anything to use one for verification. I haven't had cause to use uA or uV scales, but I'll update if and when I do. Of note is that the 87-V Max is not approved for use in residential and domestic quarters and property zones, due to the more stringent FCC rules for electromagnetic interference in domestic zones. So, if you have an instance in which the meter is out of spec. during the warrantee period, you must be using the device in a commercial or industrial zone, or the claim may be denied. I have found the Fluke '87-V' Max to be better than the '87-V' in that seals are provided for the 2 unused terminals--usually amps--making the unit ip67, or 'sealed against water entry'! I'm always cautious to keep the meter dry, but with the 87-V Max it's no big deal. The accuracy figures spec'ed by Fluke--the manufacturer--have been well within spec, at the DCV, ACA, kOHMS and DCA. I have precision instruments capable of making such an evaluation, including the aforementioned Fluke 732B DC Standard and an ESI SR104 Standard 10k Resistance Bridge, precision current shunts, and a Fluke 720A Precision Divider. I'm not claiming every example of the 87-V Max will be as good as mine. But mine is most likely near average.
Date published: 2021-10-26
Rated 5 out of 5 by from Absolutely great!! Extremely happy with this multimeter. All the features I need and more. I feel very confident using it in a very harsh environment knowing its waterproof.
Date published: 2021-09-28
Rated 5 out of 5 by from The 87V Max The 87V Max is a great meter that does everything I need it to do.
Date published: 2021-09-24
Rated 5 out of 5 by from Wonderful tool Very happy with the tool——Fluke however needs better communication.
Date published: 2021-05-30
  • y_2024, m_11, d_4, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_10, tr_14
  • loc_en_US, sid_4330750410804, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.17ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat