Fluke 120B Series Handheld Digital Oscilloscope | Fluke
English

Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes is rated 3.4 out of 5 by 9.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.78ms
  • REVIEWS, PRODUCT
  • Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes
  • 120B Series Industrial ScopeMeter® Test Tools
  • Fluke 120B
  • Fluke 120B

Key features

  • Dual-input digital oscilloscope and multimeter in a ScopeMeter® test tool
  • Available with a 40 MHz or 20 MHz oscilloscope bandwidth
  • Features Connect-and-View™ trigger simplicity for hands-off operation
  • Includes IntellaSet™ technology to automatically and intelligently adjust numerical readout based on measured signal
  • Provides a dual-input waveform and meter reading recorder for trending data over extended periods

Product overview: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

Simplified testing, more insight

The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It’s a truly integrated test tool, putting the functions of an oscilloscope, multimeter, and high-speed recorder into one, easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis, and archiving of critical test information.

 Faster electro-mechanical troubleshooting

Faster electro-mechanical troubleshooting

Troubleshoot faster and get the answers you need to keep systems up and running. Display waveforms with Connect and View™ trigger and setup technology. Automatically view related numerical measurements using Fluke IntellaSet™ technology, all without making manual measurement adjustments. With Recorder Event Detect capabilities, elusive intermittent events are captured and logged for easy viewing and analysis.

Connect-and-View™ triggering for an instant, stable display

Oscilloscope users know how difficult triggering can be. Using the wrong settings can lead to unstable waveform captures, and sometimes, even the wrong measurement data. Fluke’s unique Connect-and View™ triggering technology recognizes signal patterns, and automatically sets up the correct triggering to provide a stable, reliable, and repeatable display.

Connect-and-View™ triggering is designed to work with virtually any signal, including motor drives and control signals— without adjusting parameters, or even touching a button. Signal changes are instantly recognized, and settings are automatically adjusted providing a stable display even when measuring multiple test points in quick succession.

 Connect-and-View™ triggering for an instant, stable display
 IntellaSet™/AutoReading

IntellaSet™/AutoReading

The Auto Readings function with Fluke IntellaSet™ technology uses proprietary algorithms to intelligently analyze the measured waveform and automatically display the most appropriate numerical measurements on-screen, so you can get the data you need easier than ever before. For example, when the measured waveform is a line voltage signal, the V rms and Hz readings are automatically displayed, whereas if the measured waveform is a square wave, the V peak-peak and Hz readings are automatically displayed. Using IntellaSet™ technology in conjunction with Connect and-View™ automatic triggering you can be sure you’re seeing not only the correct waveform, but the appropriate numerical reading as well. All without touching a button.

Harmonics function measures periodic distortions

Harmonics are periodic distortions of voltage, current, or power sine waves. Harmonics in power distribution systems are often caused by non-linear loads such as switched mode dc power supplies and adjustable speed motor drives. Harmonics can cause transformers, conductors, and motors to overheat. In the Harmonics function, the Test Tool measures harmonics to the 51st. Related data such as dc components, THD (Total Harmonic Distortion), and K factor are measured to provide a complete insight into the electrical state of health of your loads.

 Harmonics function measures periodic distortions
 Comprehensive recorder modes help find intermittent faults

Comprehensive recorder modes help find intermittent faults

The toughest faults to find are those that happen only once in a while—intermittent events. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. Other factors, like line outages and sags or the starting and stopping of a motor, can also cause intermittent events resulting in equipment shutdowns. When these events happen, you may not be around to see it. But your Fluke ScopeMeter Test Tool will.

You can either plot the minimum and maximum peak measurement values or record the waveform trace. And, with expandable microSD memory, recording sessions can be done for up to 14 days. This recorder is even more powerful with the addition of Recorder Event Detect, which makes detecting and logging intermittent faults easier than ever. Just set a threshold on a meter reading or scope trace and deviations are tagged as unique events. You no longer need to search through masses of data to pinpoint faults and can quickly step from one tagged event to the next, while still having access to the full data set.

*Not all models are available in all countries. Check with your local Fluke representative.

What's in the box:

  • Fluke 120B Series Industrial ScopeMeter® 
  • (1 pair) Shielded test leads with black ground leads 
  • (1 pair) Test lead black (for grounding) 
  • (1 set) Hook clips (red, blue) 
  • (1) Banana-to-BNC adapters (black) 
  • USB angled adapter 
  • WiFi USB Adapter* (Part #4723989)
  • Switch Mode power supply, Adapter/battery charger 
  • Rechargeable Li-ion battery pack 

Specifications: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

Oscilloscope mode
Vertical
Frequency response - dc coupledWithout probes and test leads (with BB120)123B: dc to 20 MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)
With STL120-IV 1:1 shielded test leadsDC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB)
With VP41 10:1 Probe123B: dc to 20MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)
Frequency response - ac coupled (lf roll off)Without probes and test leads<10 Hz (-3 dB)
With STL120-IV 1:1 shielded test leads<10 Hz (-3 dB)
With VP41 10:1 Probe<10 Hz (-3 dB)
Rise time, excluding probes, 
test leads
123B <17.5 ns
124B and 125B <8.75 ns
Input impedanceWithout probes and test leads1 MΩ//20 pF
With BB1201 MΩ//24 pF
With STL120-IV 1:1 shielded test leads1 MΩ//230 pF
With VP41 10:1 Probe5 MΩ//15.5 pF
Sensitivity5 mV to 200 V/div
Analog bandwidth limiter10 kHz
Display modesA, -A, B, -B
Max. input voltage A and BDirect, with test leads, or with VP41 Probe600 Vrms Cat IV, 750 Vrms maximum voltage.
With BB120600 Vrms
Max. floating voltage, from any terminal to ground600 Vrms Cat IV, 750 Vrms up to 400Hz
Horizontal
Scope modesNormal, Single, Roll
Ranges (normal)Equivalent sampling123B: 20 ns to 500 ns/div,
124B and 125B: 10 ns to 500 ns/div
Real time sampling1 μs to 5 s/div
Single (real time)1 μs to 5 s/div
Roll (real time)1s to 60 s/div
Sampling rate (for both channels simultaneously)Equivalent sampling (repetitive signals)Up to 4 GS/s
Real time sampling 1 μs to 60 s/div40 MS/s
 
Trigger
Screen updateFree run, on trigger
SourceA, B
Sensitivity A and B@ DC to 5 MHz0.5 divisions or 5 mV
@ 40 MHz123B: 4 divisions
124B and 125B: 1.5 divisions
@ 60 MHz123B: N/A
124B and 125B: 4 divisions
SlopePositive, negative
 
Advanced scope functions
Display modesNormalCaptures up to 25 ns glitches and displays analog-like persistence waveform
SmoothSuppresses noise from a waveform
Glitch offDoes not capture glitches between samples
EnvelopeRecords and displays the minimum and maximum of waveforms over time
Auto set (Connect-and-View™)Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.
 
Dual input meter
The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.
Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe  uncertainty +1%. More than one waveform period must be visible on the screen.
 
Input A and input B
DC voltage (VDC)
Ranges500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy±(0.5% +5 counts)
Common mode rejection (CMRR)>100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
Full scale reading5000 counts
True-rms voltages (V ac and V ac+dc)
Ranges500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5% to 100% of range (DC coupled)DC to 60 Hz (V ac+dc)±(1% +10 counts)
1 Hz to 60 Hz (V ac)±(1% +10 counts)
Accuracy for 5% to 100% of range (AC or dc coupled)60 Hz to 20 kHz±(2.5% +15 counts)
DC rejection (only VAC)>50 dB
Common mode rejection (CMRR)>100 dB @ dc
>60 dB @ 50, 60, or 400 Hz
Full scale reading5000 counts, reading is independent of any signal crest factor.
Peak
ModesMax peak, Min peak, or pk-to-pk
Ranges500 mV, 5 V, 50 V, 500 V, 2200 V
AccuracyAccuracy Max peak or Min peak5% of full scale
Accuracy Peak-to-Peak10% of full scale
Full scale reading500 counts
Frequency (Hz)
Ranges123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz
124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
Frequency range15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy @1 Hz to 1 MHz±(0.5% +2 counts)
Full scale reading10,000 counts
RPM
Max reading50.00 kRPM
Accuracy±(0.5% +2 counts)
Duty cycle (PULSE)
Range2% to 98%
Frequency range15 Hz (1 Hz) to 30 MHz in continuous autoset
Pulse width (PULSE)
Frequency range15 Hz (1 Hz) to 30 MHz in continuous autoset
Full scale reading1000 counts
Amperes (AMP)
With current clampRangesSame as V dc, V ac, V ac+dc, or PEAK
Scale factors0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
AccuracySame as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)
Temperature (TEMP) with optional temperature probe
Range200 °C/div (200 °F/div)
Scale factor1 mV/°C and 1 mV/°F
AccuracyAs V dc (add temp. probe uncertainty)
Decibel (dB)
0 dBV1 V
0 dBm (600 Ω /50 Ω)1 mW referenced to 600 Ω or 50 Ω
dB onV dc, V ac, or Vac+dc
Full scale reading1000 counts
Crest factor (CREST)
Range1 to 10
Full scale reading90 Counts
Phase
ModesA to B, B to A
Range0 to 359 degrees
Resolution1 degree
Power (125B only)
Configurations1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)
Power factor (PF)Ratio between watts and VA range - 0.00 to 1.00
WattRMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)
Full scale reading999 counts
VAVrms x Arms
Full scale reading999 counts
VA reactive (var)√((VA)2-W2)
Full scale reading999 counts
Vpwm
PurposeTo measure on pulse width modulated signals, like motor drive inverter outputs
PrincipleReadings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
AccuracyAs Vrms for sinewave signals
 
Input A to common
Ohm (Ω)
Ranges123B and 124B500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
125B50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)
Full scale reading50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts
Measurement current0.5 mA to 50 nA, decreases with increasing ranges
Open circuit voltage<4 V
Continuity (Cont)
Beep<(30 Ω ±5 Ω) in 50 Ω range
Measurement current0.5 mA
Detection of shorts of≥1 ms
Diode
Measurement voltage@0.5 mA>2.8 V
@open circuit<4 V
Measurement current0.5 mA
Polarity+ on input A, - on COM
Capacitance (CAP)
Ranges50 nF, 500 nF, 5 μF, 50 μF, 500 μF
Full scale reading5000 counts
Measurement current500 nA to 0.5 mA, increases with increasing ranges
 
Advanced meter functions
Zero SetSet actual value to reference
AutoHold (on A)Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
Fixed decimal pointActivated by using attenuation keys
 
Cursor Readout (124B and 125B)
SourcesA, B
Single vertical lineAverage, min and max readout
Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)
Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
Harmonics values in POWER QUALITY mode.
Dual vertical linesPeak-peak, time distance and reciprocal time distance readout
Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
Dual horizontal linesHigh, low and peak-peak readout
Rise or fall timeTransition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only 
possible in single channel mode)
AccuracyAs oscilloscope accuracy
 
Recorder
The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).
The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.
Meter readings
Measurement SpeedMaximum 2 measurement/s
Record Size (min, max, average)2 M readings for 1 channel
Recorded Time Span2 weeks
Maximum number of events1024
Waveform record
Maximum sample rate400 K sample/s
Size Internal memory400 M samples Recorded Time
Span internal memory15 minutes at 500 μs/div
11 hours at 20 ms/div
Record Size SD card1.5 G samples
Recorded Time Span SD card11 hours at 500 μs/div
14 days at 20 ms/div
Maximum number of events64
 
Power Quality (125B only)
ReadingsWatt, VA, var, PF, DPF, Hz
Watt, VA, var ranges (auto)250 W to 250 MW, 625 MW, 1.56 GW
When selected: total (% r)±(2% + 6 counts)
When selected: fundamental (% f)±(4% + 4 counts)
DPF0.00 to 1.00
PF0.00 to 1.00, ±0.04
Frequency range10.0 Hz to 15.0 kHz
40.0 Hz to 70.0 Hz
Number of HarmonicsDC to 51
Readings / Cursor readings 
(fundamental 40 Hz to 70 Hz)
Vrms / Arms /WattEach harmonic from fundamental maybe selected for individual readings
Includes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)
 
BusHealth tester (Fluke 125B only)
TypeSubtypeProtocol
AS-iNEN-EN50295
CANISO-11898
Interbus SRS-422EIA-422
ModbusRS-232RS-232/EIA-232
RS-485RS-485/EIA-485
Foundation FieldbusH161158 type 1, 31.25 kBit
ProfibusDPEIA-485
PA61158 type 1
 
Miscellaneous
DisplayType5.7-inch color active matrix TFT
Resolution640 x 480 pixels
Waveform DisplayVertical10 div of 40 pixels
Horizontal12 div of 40 pixels
PowerExternalVia Power Adapter BC430
Input voltage10 V DC to 21 V DC
Power consumption5 W typical
Input connector5 mm jack
InternalVia Battery Pack BP290
Battery powerRechargeable Li-Ion 10.8 V
Operating time7 hours with 50% backlight brightness
Charging time4 hours with test tool off,  7 hours with test tool on
Allowable ambient temp0 to 40 °C (32 to 104 °F) during charging
MemoryInternal memory can store 20 data sets  (screen waveform and setup)Micro SD card slot with optional SD card  (max size of 32 GB)
MechanicalSize259 x 132 x 55 mm 
(10.2 x 5.2 x 2.15 in)
Weight1.4 kg (3.2 lb) including battery pack
InterfaceOptically isolatedTransfer screen copies (bitmaps), settings and data
USB to PC/laptopOC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®.
Optional WiFi adapterFast transfer of screen copies (bitmaps), settings and data to PC/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.
 
Environmental
EnvironmentalMIL-PRF-28800F, Class 2
TemperatureBattery Operation0 to 40 °C (32 to 104 °F)
Power Adapter Operation0 to 50 °C (32 to 122 °F)
Storage-20 to 60 °C (-4 to 140 °F)
Humidity (Operating)@ 0 to 10 °C (32 to 50 °F)Non-condensing
@ 10 to 30 °C (50 to 86 °F)95%
@ 30 to 40 °C (86 to 104 °F)75%
@ 40 to 50 °C (104 to 122 °F)45%
Storage@ -20 to 60 °C (-4 to 140 °F)Non-condensing
AltitudeOperating at 3 km (10,000 feet)CAT III 600 V
Operating at 2 km (6,600 feet)CAT IV 600 V
Storage12 km (40,000 feet)
EMC electromagnetic compatibilityInternationalIEC 61326-1: Industrial, CISPR 11:  Group 1, Class A
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Wireless radio with adapterFrequency range2412 MHz to 2462 MHz
Output power<100 mW
Enclosure protectionIP51, ref: EN/IEC60529
SafetyGeneralIEC 61010-1: Pollution Degree 2
MeasurementIEC 61010-2-033: CAT IV 600 V/CAT III 750 V
Max. input voltage input A and BDirect on input or with leads600 Vrms CAT IV for derating
With Banana-to-BNC Adapter BB120600 Vrms for derating
Max. floating voltage from any terminal to ground600 Vrms Cat IV, 750 Vrms up to 400 Hz

Models: Fluke 120B Series Industrial ScopeMeter handheld Oscilloscopes

FLUKE-125B/NA
Fluke 125B Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz), North America version

Includes:

  • Fluke 125B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • 10:1 Voltage Probe
  • i400s AC Current Clamp
  • USB Angled Adapter
  • WiFi USB Adapter*
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack
FLUKE-123B/NA/S
Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope (20 MHz), North America version, with Soft Carrying Case, Magnetic Hanger, FlukeView® ScopeMeter® Software for Windows®, Screen Protector

Includes:

  • Fluke 123B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • USB Angled Adapter
  • WiFi USB Adapter*
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack
  • Soft Carrying Case
  • Magnetic Hanger
  • FlukeView® ScopeMeter® Software for Windows®
  • Screen Protector
FLUKE-123B/NA
Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope (20 MHz), North America version

Includes:

  • Fluke 123B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • USB Angled Adapter
  • WiFi USB Adapter*
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack
FLUKE-124B/NA
Fluke 124B Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz), North America version

Includes:

  • Fluke 124B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • 10:1 Voltage Probe
  • USB Angled Adapter
  • WiFi USB Adapter*
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack
FLUKE-124B/NA/S
Fluke 124B Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz), North America version, with Soft Carrying Case, Magnetic Hanger, FlukeView® ScopeMeter® Software for Windows®, Screen Protector

Includes:

  • Fluke 124B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • 10:1 Voltage Probe
  • USB Angled Adapter
  • WiFi USB Adapter*
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack
  • Soft Carrying Case
  • Magnetic Hanger
  • FlukeView® ScopeMeter® Software for Windows®
  • Screen Protector
FLUKE-125B/NA/S
Fluke 125B Industrial ScopeMeter® Hand-Held Oscilloscope (40 MHz), North America version, with Soft Carrying Case, Magnetic Hanger, FlukeView® ScopeMeter® Software for Windows®, Screen Protector

Includes:

  • Fluke 125B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • 10:1 Voltage Probe
  • i400s AC Current Clamp
  • USB Angled Adapter
  • WiFi USB Adapter*
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack
  • Soft Carrying Case
  • Magnetic Hanger
  • FlukeView® ScopeMeter® Software for Windows®
  • Screen Protector

Could I measure DC Power (Watt) with the 125b (for troubleshooting and monitoring 48V PV inverters with battery storage) using a Fluke i410 AC/DC clamp sensor? Or is it forced to AC only? Thanks in advance!

Asked by: Daniel Ardelian
The Fluke-125B is can support both AC and DC applications and using the Fluke i410 allows both AC or DC current.
Answered by: FlukeCorporation
Date published: 2024-09-18

Can the 125B be used to test OSDP (RS-485 for security) cable?

Asked by: smitheesolutions
Please contact Fluke's tech support team at tech.support@fluke.com or 800-443-5853.
Answered by: FlukeCorporation
Date published: 2024-03-28
  • y_2024, m_11, d_4, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_3840951124020, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 22.87ms
  • QUESTIONS, PRODUCT
Rated 1 out of 5 by from Good hardware, faulty firmware Although the hardware and the idea behind this industrial scope is great, it is just riddled with firmware bugs. We purchased a unit (with the latest firmware- version 1.14.00) and were immediately troubled with detrimental issues. The issues are are as follows: 1- The instrument does not turn ON after entering "sleep mode", and must be turned ON using the "factory reset" method. 2- The "charge" symbol does not always switch to the "battery" symbol when the charger is removed and the instrument thinks it's still being charged. When this happens, the instrument does NOT turn ON once its turned OFF. Not even with the "factory reset" method. Although removing the battery for a few minutes solves this problem. Since we are limited on time and wanted to rule out a defective unit, we purchased a second unit, but were surprised to find that they both have the exact same problems. This just seems to be the cause of unchecked and inferior firmware. We are holding on to both units for now until we receive instruction from Fluke.
Date published: 2024-05-19
Rated 5 out of 5 by from Nice Display, Fluke Quality Used various Fluke scope meters for over 25 years. The display on this unit is spectacular. Debated on other cheaper brands available lately but decided to pay double the price for a Fluke as to avoid the hassle and time questioning the reliability of other products. Chose the 123B for the value as I don't need anything over 20Mhz. The test leads are super heavy duty. Bought a 410 current clamp for AC/DC amps. Everything I need!
Date published: 2020-10-25
Rated 4 out of 5 by from Fluke 124B Purchased the 124B few months ago. I mostly use it to measure the voltage waveform of VSD and UPS, which help me to solve the problems quickly and safely. However the device works great, but i found that there is something odd when measuring DC voltage i.e. The voltage value will change while moving the waveform position up and down. Firmware version V1.12.00
Date published: 2019-09-15
Rated 1 out of 5 by from Great features but not working We bought it in July 2018 124B. The recording feature should help us find periodic errors. We find that scoped restarts and timestamps do not match the recorded image. We have contacted fluke several times, but it does not seem to be resolved.
Date published: 2018-11-14
Rated 2 out of 5 by from There are software problems We have repeatedly provided information but have problems with the software and still can not resolve it.
Date published: 2016-12-24
Rated 4 out of 5 by from Nice tool to have We bought this scope ( Fluke 125 ) to troubleshoot several Fieldbus trunks. Tool was able to find noise and distortion affecting this site where other tools from different vendors couldn't. It was a nice feeling finding the "smoking gun"
Date published: 2016-12-09
Rated 5 out of 5 by from First Scopemeter Great Portable Oscilloscope for testing VFD's and power conditions if not on a Delta. This is my first one and don't know how we survived without one. If you are working with Delta transformer I recommend a 190 Series and with only 2 inputs you cannot data you may want. Went with the 125B to save a little cost over the 190 and very happy with it. This has really helped with properly diagnosing VFD issues we were having and recording intermittent issues. I would recommend!
Date published: 2016-12-07
Rated 4 out of 5 by from Great meter extremely useful in the classroom We purchased Fluke 125B scopemeters for use in the electrical labs at the community college where I am a professor, and I found them to be extremely useful when educating students about AC wave forms, AC power (true power (watts), apparent power (VA), reactive power (VAR) and power factor). I also use the meters when teaching about power quality and harmonics. The color display is so much better then the black & white display on the 43B. I have only been using the meters for one semester but so far I have found them to be excellent and durable. The students learn the concepts so much easier when they can see the waveforms for themselves on a meter display, on the projector screen, or on their cell phone using Fluke connect. Our Fluke representative, Curt Geeting, has always been a big help when choosing Fluke products to best suit our needs.
Date published: 2016-12-07
  • y_2024, m_11, d_4, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_9
  • loc_en_US, sid_3840951124020, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.61ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.