Fluke 700PTP-1 Pneumatic Test Pump | Fluke
English

Fluke 700PTP-1 Pneumatic Test Pump

Model#: Fluke 700PTP-1 Part#: 2811774 UPC#: 0 95969 39771 1
Fluke 700PTP-1 Pneumatic Test Pump is rated 2.0 out of 5 by 4.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.19ms
  • REVIEWS, PRODUCT
  • Fluke 700PTP-1 Pneumatic Test Pump

Key features

  • Pump can be easily cleaned without disassembly
  • The vernier can be used as a stand-alone low pressure calibration source
  • Two pressure ports allowing simultaneous connection:
    • 1/4 in NPT female fitting for the reference gauge or pressure module
    • 1/8 F-NPT female fitting for the unit under test
  • Adjustable stroke length can be set to limit the pressure per stroke
  • Vacuum range from -12.7 psi or -.87 bar, pressure range up to 600 psi or 41 bar
In stock
$1,058.99
FREE Shipping
30-day Returns

Product overview: Fluke 700PTP-1 Pneumatic Test Pump

The Fluke-700PTP-1 pneumatic test pump is capable of supplying pressures up to 600 psi, 40 bar.

For use with 700 series pressure modules or test gauges. Can be directly connected to the reference port consolidating two separate pieces when performing pressure calibration and testing. Can also be used with 717 pressure calibrators. Ideal for calibrating pressure transmitters, pressure switches and pressure gauges up to 600 PSI/40 bar.

Specifications: Fluke 700PTP-1 Pneumatic Test Pump

Mechanical and General Specifications
Size (L x W x D)8.7 x 4.8 x 3.5 in (220 x 122 x 89 mm)
Weight1.03 lb (467 g)
WarrantyOne year
MaterialWetted materials: aluminum, silicon, neoprene, stainless steel, Buna-N

Models: Fluke 700PTP-1 Pneumatic Test Pump

Fluke 700PTP-1

Pneumatic Test Pump

Part#: 2811774
UPC#: 0 95969 39771 1
  • ¼ in NPT male to ¼ in BSP female
  • 1 meter of hose
  • (2) ⅛ in NPT male quick connects
  • ⅛ in NPT female to ¼ in BSP female
  • Seal Kit
  • Instruction sheet

How in the heck does this fine adjustment work? Seems to do nothing!

Asked by: Bake
Please contact Fluke's tech support team at tech.support@fluke.com or 800-443-5853.
Answered by: FlukeCorporation
Date published: 2024-04-02
  • y_2024, m_11, d_9, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_3839988596788, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 80.27ms
  • QUESTIONS, PRODUCT
Rated 2 out of 5 by from Poor design, not robust Stray away from this pump and the low pressure pump from Fluke. Both broke the handle. The are not robust. They seem made of cheap plastic and the torx screws they have always come loose after a one or two uses. The side pressure ports is too recessed, so I scrape of the pump decal while tightening a fitting. Really a bad and expensive choice for pump.
Date published: 2023-03-21
Rated 2 out of 5 by from weak parts 1 year old and the handle broke. cheap plastic is used for the handle
Date published: 2021-04-30
Rated 1 out of 5 by from Hand pump calibration I buy this pump because my old pump was 15 year different manufacture this is only 2 year and there always problem with building pressure poor design will ever buy this pump again.
Date published: 2019-10-12
Rated 3 out of 5 by from Handel with care The pump worked great right out of the box. The one issue I had with it was its not as rugged as I thought it should be. While using it in the field to calibrate a differential pressure flow meter the pump and pressure module fell landing the adjustment / bleed off valve breaking it. Thus far I've found no repair parts.
Date published: 2013-10-06
  • y_2024, m_11, d_8, h_5
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_US, sid_3839988596788, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.07ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat