Solar Tools Kit with 87V Max Digital Multimeter and Test Leads
Model#: FLK-87VMAX-PVLEAD1 Part#: 5337412 UPC#: 1 95112 04123 9
Key features
- Withstands drops up to 4-meters (13 feet) with industrial strength casing and holster
- Waterproof, dustproof IP67 case for the most extreme work sites
- Meter rated to CAT III 1000 V / CAT IV 600 V
- Solar PV test lead sets are designed for use with meters that accept 4mm banana plugs, rated to CAT III 1000 V / CAT IV 600 V
$639.99
Product overview: Solar Tools Kit with 87V Max Digital Multimeter and Test Leads
The 87V MAX is the ideal electrical troubleshooting solution for solar inverters, combiner boxes and battery storage systems. The 87V MAX is built with an IP67 rated, industrial-strength case and a removable holster. The holster doubles as a test probe holder for easier, one-handed operation. This meter is fully waterproof and dust proof keep working reliably no matter where your job takes you. Safely connect the Solar PV test leads to the meter to validate voltage from individual panels or a series of panels in a PV array.
Key functions of the solar clamp meter and Solar PV test leads:
- Measure voltage of PV arrays safely and accurately
- IP67 rated meter can withstand harsh outdoor environments
- Meter is designed to survive drops up to 4-meters (13 feet)
- Solar PV leads comply to IEC / EN 61010-031
Solar Tools Kit with 87V Max Digital Multimeter and Test Leads
What's in the box:
- Fluke 87V MAX True-rms Digital Multimeter
- TL175 TwistGuard® test leads
- AC175 Alligator clips
- 80BK-A temperature probe
- Removable holster with test lead storage
- Three AA batteries (installed)
- Pomona PVLEAD1 Solar PV to 4 mm Test Lead Set
Specifications: Solar Tools Kit with 87V Max Digital Multimeter and Test Leads
Specifications: Fluke 87V MAX True-rms Digital Multimeter
Electrical Specifications | ||
DC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum resolution | 0.1 mV | |
AC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.7% + 4) true-rms | |
AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
Maximum resolution | 0.1 mV | |
DC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(0.2% + 2) | |
Maximum resolution | 0.1 µA | |
AC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(1.0% + 2) true-rms | |
Maximum resolution | 0.1 µA | |
Resistance | Range | 0.1 Ω to 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Range | 0.01 nF to 9999 μF |
Accuracy | ±(1% + 2) | |
Maximum resolution | 0.01 nF | |
Frequency | Range | 0.5 Hz to 199.99 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum resolution | 0.01 Hz | |
Duty cycle | Maximum duty cycle | 99.9% |
Accuracy | ±(0.2% per kHz + 0.1%) | |
Maximum resolution | 0.1% | |
Temperature measurement range | –200.0 °C to 1090 °C –328.0 °F to 1994.0 °F excluding probe | |
80 BK temperature probe | –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater | |
Conductance | Maximum conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum resolution | 0.01 nS | |
Diode test | Range | 2 V |
Resolution | 0.001V | |
Accuracy | ±(1% + 1) | |
Diagnostics and data storage | Peak Min/Max | 250 μS |
Min/Max/Avg | Yes | |
Reading hold/Auto (Touch) Hold | Yes | |
Relative reference | Yes | |
Display | Digital | 6000 counts updates 4/second 19,999 counts in high–resolution mode |
Analog bar graph | 32 segments, updates 40/second | |
Backlight | Two level | |
Low pass filter (VFD measurements) | Yes | |
Input Alert™ | Yes | |
Safety Specifications | ||
Safety rating | IEC61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V | |
Agency approvals | CE, CSA | |
Mechanical and General Specifications | ||
IP rating | IEC 60529: IP67 | |
Power | Three AA batteries. 800 hours typical, without backlight | |
Size | 6.0 x 10.1 x 21.5 cm (with holster) | |
Weight | 698.5 g (with holster) | |
Warranty | Limited lifetime | |
Environmental Specifications | ||
Operating temperature | -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C | |
Storage temperature | -40 °C to + 60 °C | |
Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) | |
Operating altitude | 2000 m |
Specifications: Pomona PVLEAD1 Solar PV Connector to 4 mm Test Lead Set
PVLEAD1 | PVLEAD3 | |
Solar PV Connector to 4mm Test Lead Set | Solar PV Clamp Test Lead Set | |
Contact | Brass, Nickel Plated | Brass, Nickel Plated |
Length | 60” | 36”, 12” |
Voltage | CAT III 1000V, | CAT III 1000V, |
CAT IV 600V | CAT IV 600V | |
Current | 20 amp | 20 amp |
Standards | IEC 61010-031 | IEC 61010-031 |
Models: Solar Tools Kit with 87V Max Digital Multimeter and Test Leads
FLK-87VMAX-PVLEAD1
Part#: 5337412UPC#: 1 95112 04123 9
Includes:
- Fluke 87V MAX True-rms Digital Multimeter
- TL175 TwistGuard® test leads
- AC175 Alligator clips
- 80BK-A temperature probe
- Removable holster with test lead storage
- Three AA batteries (installed)
- Pomona PVLEAD1 Solar PV Connector to 4 mm Test Lead Set