Key features
Fluke 789 Temperature Kit features:
- Unique new wireless measurement logging capability
- Temperature measurement from -200 °C to 1372 °C using the t3000 FC
- 24 V Loop power supply
- HART mode setting with loop power (adds 250 ohm resistor)
- 100% larger dual display
- 1200 ohm drive capability on mA source
- Enhanced backlight with two brightness settings
- 0% to 100% mA Span Check buttons to toggle between 4 and 20 mA
- Infrared I/O serial port compatible with
- FlukeView® Forms Software Version 2.1
- Externally accessible fuses for easy replacement
These 787 features are also included in the 789:
- DMM designed to meet 1000 volt IEC 1010 CAT III standards
- Precision 1000 V, 440 mA True-RMS digital multimeter
- Frequency measurement to 20 kHz
- Min/Max/Average/Hold/Relative modes
- Diode test and continuity beeper
- Simultaneous mA and% of scale readout
- 20 mA DC current source/loop calibrator/ simulator
- Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
- Externally accessible battery for easy battery changes
Product overview: Fluke 789 FC ProcessMeter™ and Temperature Kit
See How It Works
Fluke Connect FAQs
Double your power
The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals, combining the functionality of a loop calibrator with the power of a digital multimeter. By equipping the 789 with a temperature measurement module and the wireless data logging capabilities of Fluke Connect® with ShareLive™ video call, process technicians can now do a lot more while carrying a lot less. And with its built-in, selectable 250 ohm HART® resistor, it eliminates the need to carry a separate resistor with you.
Use the included FC Connector with the Fluke 789 and get the full benefits of the Fluke Connect® app. Download it now and get started.
Specifications: Fluke 789 FC ProcessMeter™ and Temperature Kit
Fluke 789 ProcessMeter™ with Fluke Connect™
Specifications | ||
Current measurement | Range | 0-1 A AC or DC |
Resolution | 1 mA | |
Accuracy | 0.2% + 2 LSD (DC) | |
Range | 0-30 mA | |
Resolution | 0.001 mA | |
Accuracy | 0.05% + 2 lSD | |
Current sourcing | Range | 0-20 mA or 4-20 mA |
Resolution | 0.05% of span | |
Drive capability | 24 V Compliance or 1200 Ω @ 20 mA | |
Frequency | to 19.999 kHz, 0.005% + 1 LSD | |
Continuity | Beeps for resistance < 100 Ω | |
Voltage measurement | Range | 0-1000 V AC (true-rms) or DC |
Resolution | 0.1 mV to 1.0 V | |
Accuracy | 0.1% Rdg + 1 LSD (V DC) | |
Resistance measurement | to 40 MΩ, 0.2% + 1 LSD | |
Diode test | 2.0 V shoes diode voltage drop | |
Display current and % of span | Yes | |
Auto Step, Auto Ramp | Yes | |
Environmental Specifications | ||
Operating temperature | -20°C to 55°C | |
Storage temperature | -40°C to 60°C | |
Humidity (without condensation) | 95% up to 30°C 75% up to 40°C 45% up to 50°C 35% up to 55°C | |
Temperature coefficient | 0.05 x (specified accuracy) per °C (for temperatures < 18°C or > 28°C) | |
Safety Specifications | ||
Electrical safety | Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92 | |
Overvoltage category | IEC 1010-1 CAT III 1000 V IEC 1010-1 CAT IV 600 V | |
Maximum voltage | 1000 V RMS | |
Mechanical and General Specifications | ||
Size (H x W x L) | 50 x 100 x 203 mm (1.25 x 3.41 x 7.35 in) | |
Weight | 610 g (1.6 lbs) | |
Batteries | 4 AA alkaline batteries | |
Warranty | 3 years | |
Battery life | 140 hours typical (measurement), 10 hours typical (sourcing 20 mA) | |
Shock and vibration | Random, 2 g, 5-500 Hz 1 meter drop test |
Fluke t3000 FC Wireless K-Type Temperature Module
General Specifications | ||||
Range K-Type | -200°C to 1372°C | |||
Resolution | 0.1°C | |||
Accuracy | ±[0.5% + 0.5°C] counts | |||
Input terminals | K-type mini | |||
LCD w/backlight | 3 ½ digits | |||
Log rate/interval | 1 sec minimum/adjustable by PC | |||
Battery type | 2 AA, NEDA 15 A, IEC LR6 | |||
Battery life | 400 hours | |||
Memory | Record up to 65,000 readings | |||
RF communications | 2.4 GHZ ISM Band | |||
RF communication range | Open air, unobstructed | Up to 20 m | ||
Obstructed, sheetrock wall | Up to 6.5 m | |||
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |||
Operating temperature | -10°C to +50°C | |||
Storage temperature | -40°C to +60°C | |||
Temperature coefficient | 0.01% of reading +0.03°C per °C | |||
Temperature scale | ITS-90 | |||
Operating humidity | 90% at 35°C, 75% at 40°C, 45% at 50°C | |||
Altitude | Operating | 2,000 m | ||
Storage | 12,000 m | |||
EMC | EN 61326-1:2006 | |||
Safety compliance | IEC 61010-1, CAT I, 3rd edition Pollution Degree 2 | |||
Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |||
Ingress Protection (IP) rating | IP42 | |||
Pollution Degree | 2 | |||
Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |||
Weight | .22 kg (8 oz) | |||
Not compatible with Fluke CNX test tools |
Models: Fluke 789 FC ProcessMeter™ and Temperature Kit
UPC#: 0 95969 72688 7
Includes:
- Fluke 789 ProcessMeter
- Fluke t3000 FC Wireless K-Type Temperature Module
- Fluke ir3000 FC Connector
- TL71 Premium Test Lead Set
- AC72 Alligator Clips
- Four (4) AA alkaline batteries (installed)
- Users' manual
- Quick reference guide