Early reports from the field suggest that the new Fluke 772 and 773 Milliamp Process Clamp Meters may be game changers, breaking new ground for technicians in the HVAC controls industry. With the feature sets these meters offer, troubleshooting of the most common problems in modern control systems becomes a snap.
Clamp meter readings: problems and solutions
Since a small increase in current flow to a motor produces a proportionately larger amount of heat, motor amperage exceeding nameplate values should be carefully investigated as a possible cause. These overload trips, though often caused by motor loading issues, can also indicate bearing failure, insulation breakdown or voltage unbalance.
Using accessory current clamps with Fluke Digital Multimeters
Accessory current clamps expand a multimeter's flexibility and measurement capabilities by allowing it to measure up to thousands of amps.
Why is there an arrow on your current clamp?
Learn why on all current clamps and current clamp accessories, there is an arrow placed close to the beak or inside the beak opening.
Case study: Electric utility plays it safe...
The safety rated Fluke T+Pro gets field-tested by non-electricians. Larger buttons for gloved hands and a battery life indicator helped to make the transition from the old solenoid-based testers to the T+Pro much easier.
クランプメーターとデジタルマルチメーターの比較
クランプ・メーター vs マルチメーター。デジタル・マルチメーターは電流測定機能がありますが、本質的には電圧測定ツールです。クランプ・メーターには電圧測定機能もありますが、基本的に電流測定ツールです。これらは明らかに異なる機器であり、それぞれに独自の利点があります。
What is a clamp meter?
Clamps measure current. Probes measure voltage. Having a hinged jaw integrated into an electrical meter allows technicians to clamp the jaws around a wire, cable and other conductor at any point in an electrical system, then measure current in that circuit without disconnecting/deenergizing it.
How to measure current with a clamp accessory
How to measure current with a digital multimeter plus clamp accessory.
Troubleshooting 4 to 20 mA Process Control Systems without Breaking the Loop
Troubleshooting 4 to 20 mA (milliamp) process control systems without breaking the loop using Fluke 773 Milliamp Process Clamp Meter
Leakage current measurement basics
On circuits protected by GFCIs (Ground Fault Current Interrupters), leakage current can cause unnecessary and intermittent tripping. In extreme cases, it can cause a rise in voltage on accessible conductive parts.