Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture
คุณลักษณะสำคัญ
- Share results with your team using ShareLive™ video call (requires ir3000 FC wireless connector [sold separately] and no-cost Fluke Connect mobile app).
- TrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred.
- Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.
- Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy.
- Low Pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment.
- LoZ Volts. Low impedance voltage function for eliminating ghost voltages. Also recommended when testing for absence or presence of live power.
- Adjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event.
- Large 50,000 count, 1/4 VGA dot matrix display with white backlight.
- Measure up to 10 A (20 A for 30 seconds).
- 100 mF capacitance range.
ภาพรวมผลิตภัณฑ์: Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture
Now compatible with Fluke Connect® Mobile App
The 289 is the next generation high performance industrial logging multimeter designed to solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment. With the ability to log data and review it graphically on-screen, you can solve problems faster and help minimize downtime. Let the new 289 be your watchdog for systems or processes while you are off doing other jobs. Now communicate wirelessly with your iOS and Android smart devices with the Fluke Connect mobile app and ir3000 FC wireless connector (sold separately).
ข้อมูลจำเพาะ: Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture
Specifications | ||
Function | ||
DC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic accuracy | 0.025% | |
AC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic accuracy | 0.4% (True-RMS) | |
DC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Basic accuracy | 0.05% | |
AC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Basic accuracy | 0.6% (True-RMS) | |
Temperature (excluding probe) | Range / resolution | -200.0°C to 1350.0°C (-328.0°F to 2462.0°F) |
Basic accuracy | 1.0% | |
Resistance | Range / resolution | 50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
Basic accuracy | 0.05% | |
Capacitance | Range / resolution | 1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF |
Basic accuracy | 1.0% | |
Frequency | Range / resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
Basic accuracy | 0.005% | |
Connectivity | Optional infrared connector via Fluke ir3000 FC | |
General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V | |
Battery type | 6 AA alkaline batteries, IECLR6 | |
Battery life | 100 hours minimum, 200 hours in logging mode | |
Temperature | Operating | -20°C to 55°C |
Storage | -40°C to 60°C | |
Relative humidity | 0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C) | |
Electromagnetic compatibility | EMC EN61326–1 | |
Vibration | Random vibration per MIL-PRF-28800F Class 2 | |
Shock | 1 meter drop per IEC/EN 61010–1 3rd Edition | |
Size (H x W x L) | 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) | |
Weight | 870.9 g (28 oz) | |
Multiple on screen displays | Yes | |
True-RMS AC bandwidth | 100 kHz | |
dBV/dBm | Yes | |
DC mV resolution | 1 μV | |
Megohm range | Up to 500 MΩ | |
Conductance | 50.00 nS | |
Continuity beeper | Yes | |
Battery/fuse access | Yes/Yes | |
Elapse time clock | Yes | |
Time of day clock | Yes | |
Min-max-avg | Yes | |
Duty cycle | Yes | |
Pulse width | Yes | |
Isolated optical interface | Yes | |
Auto/touch hold | Yes | |
Reading memory | Yes | |
Log to PC | Yes | |
Interval/event logging | Yes | |
Logging memory | Up to 15,000 readings | |
Wireless connectivity (optional) | Yes |
รุ่น: Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture
True-rms Electronics Logging Multimeter with TrendCapture
Includes:
- 289 True-RMS Industrial Logging Multimeter
- TL71 Test Leads
- AC175 Alligator Clips
- Batteries – 6 AA Installed
Requires Fluke ir3000 FC Infrared Connector for Fluke Connect communication
คู่มือและแหล่งข้อมูล: Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture
- Connecting a thermal imager to your iPhone
- Connecting multiple tools at the same time with Fluke Connect®
- Connecting the T3000 FC with the Fluke Connect™ app
- Fluke 289: Virtual Product Tour
- Fluke ScopeMeter Test Tools: Keithly Electric's Tough Standards Demand a Powerful Arsenal of Tools
- How to create an equipment baseline with EquipmentLog™ history
- How to email a measurement using the Fluke Connect app
- How to record measurements and graphs
- How to save measurements to EquipmentLog™ history
- How to share measurements on equipment using the Fluke Connect™ app
- Identifying intermittent conditions with TrendIt™ graphs
- Introduction to 789FC
- Measurement history in one place using EquipmentLog™ history
- Measuring from a safe distance using the Fluke Connect™ app
- Performing predictive maintenance with Fluke Connect™
- Saving measurements with AutoRecord™ measurements
- Share equipment health with EquipmentLog™ history
- Using ShareLive™ video call to share live measurements and video
- Viewing and graphing three phase measurements