Fluke i410 AC/DC Current Clamp
Tính năng chính
- Battery-powered Hall-effect probe measures 1A to 400 A
- 1mV/Amp output guarantees easy reading on your meter
- Take accurate current readings without breaking the circuit
- Maximum conductor Ø 32 mm
- CAT III 600 V safety rating
- Also available with softcase for DMM and clamp (i410 kit)
- One year warranty
Tổng quan sản phẩm: Fluke i410 AC/DC Current Clamp
The Fluke i410 AC/DC current clamp expands the functionality of digital multimeters and measures up to 400 amps for both AC and DC current. The Large clamp claw gives you access to difficult to reach areas. The kit includes a handy carrying case.
Thông số kỹ thuật: Fluke i410 AC/DC Current Clamp
Specifications | |
Measurement type | Hall sensor |
Nominal current range | 400 A, AC/DC |
Continuous current range | 1 A - 400 A AC/DC |
Maxium non-destructive current | 400 A |
Lowest measureable current | 0.5 A |
Basic accuracy | 3.5% + 0.5 A (% reading + floorspec) |
Useable frequency | DC - 3 kHz |
Output level(s) | 1 mV/A |
Zerro error adjustmemt | Yes |
Safety Specifications | |
Safety | CAT III, 600 V |
Maximum voltage | 600 V |
Mechanical and General Specifications | |
Warranty | 1 year |
Battery life | 9 V, 60 h |
Maximum conductor diameter | 30 mm 2 x 25 mm |
Output cable length | 1.6 m |
Shrouded banana plugs | Yes |
Model: Fluke i410 AC/DC Current Clamp
i410
AC/DC Current Clamp